Background: The acceptance of coronary CT angiogram (CCTA) scans in the management of stable angina has led to an exponential increase in studies performed and reported incidental findings, including pulmonary nodules (PN). Using low-dose CT scans, volumetry tools are used in growth assessment and risk stratification of PN between 5 and 8 mm in diameter. Volumetry of PN could also benefit from the increased temporal resolution of CCTA scans, potentially expediting clinical decisions when an incidental PN is first detected on a CCTA scan, and allow for better resource management and planning in a Radiology department. This study aims to investigate how cardiopulmonary hemodynamic factors impact the volumetry of PN using CCTA scans. These factors include the cardiac phase, vascular distance from the main pulmonary artery (MPA) to the nodule, difference of the MPA diameter between systole and diastole, nodule location, and cardiomegaly presence.

Materials And Methods: Two readers reviewed all CCTA scans performed from 2016 to 2019 in a tertiary hospital and detected PN measuring between 5 and 8 mm in diameter. Each observer measured each nodule using two different software packages and in systole and diastole. A multiple linear regression model was applied, and inter-observer and inter-software agreement were assessed using intraclass correlation.

Results: A total of 195 nodules from 107 patients were included in this retrospective, cross-sectional and observational study. The regression model identified the vascular distance (p < 0.001), the difference of the MPA diameter between systole and diastole (p < 0.001), and the location within the lower or posterior thirds of the field of view (p < 0.001 each) as affecting the volume measurement. The cardiac phase was not significant in the model. There was a very high inter-observer agreement but no reasonable inter-software agreement between measurements.

Conclusions: PN volumetry using CCTA scans seems to be sensitive to cardiopulmonary hemodynamic changes independently of the cardiac phase. These might also be relevant to non-gated scans, such as during PN follow-up. The cardiopulmonary hemodynamic changes are a new limiting factor to PN volumetry. In addition, when a patient experiences an acute or deteriorating cardiopulmonary disease during PN follow-up, these hemodynamic changes could affect the PN growth estimation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8932130PMC
http://dx.doi.org/10.1186/s12880-022-00774-wDOI Listing

Publication Analysis

Top Keywords

ccta scans
16
cardiopulmonary hemodynamic
8
hemodynamic factors
8
8 mm diameter
8
vascular distance
8
systole diastole
8
regression model
8
ccta
5
scans
5
impact cardiopulmonary
4

Similar Publications

Background: There is limited data showing the predictive accuracy of traditional cardiovascular risk scores (CVRS) to predict asymptomatic coronary artery disease (CAD) determined by coronary computed tomography angiography (CCTA).

Methods: Asymptomatic individuals without known CAD undergoing a screening CCTA and sufficient data to calculate their CVRS, were extracted retrospectively. Atherosclerosis was extracted using natural language processing of the CCTA report, including the coronary artery calcium score (CACS) and the extent and severity of CAD.

View Article and Find Full Text PDF

This study aims to explore the feasibility of applying the "Three-Low" technique (low injection rate, low iodine contrast volume, low radiation dose) in coronary CT angiography (CCTA). We prospectively collected data from 90 patients who underwent CCTA at our hospital between 2021 and 2024. The patients were randomly assigned to either the experimental group (n = 45) or the control group (n = 45).

View Article and Find Full Text PDF

Diagnostic Accuracy of Dynamic Stress Myocardial CT Perfusion Compared with Invasive Physiology in Patients with Stents: The Advantage 2 Study.

Radiology

December 2024

From the Centro Cardiologico Monzino, IRCCS, Via C. Belgioioso 173, Milan, Italy (D.A., S.M., D.T., E.C., G.L., S. Galli, G.M., L.G., G.T., S.T., S. Gili, P.M., P.O., V.M., D.M., M.S., C.G., E.M., A.B., M.E.M., A.A., A F., G.P., A.L.B.); Department of Biomedical and Clinical Sciences, University of Milan, Milan, Italy (D.A.); IRCCS Ospedale Galeazzi Sant'Ambrogio, Milan, Italy (E.C., G.M., L.G., V.M., D.M., M.S., E.G., P.P., E.M., A.L.B.); Cardiovascular Center Aalst, OLV Hospital, Aalst, Belgium (J.S., M.B., E.G., P.P., K.S., T.M., C.C.); Department of Medicine, Division of Cardiology, Showa University School of Medicine, Tokyo, Japan (K.S., T.M.); Department of Biomedical, Surgical and Dental Sciences, University of Milan, Milan, Italy (G.P.); and Department of Radiology, Azienda Ospedaliera di Padova, Padua, Italy (L.Z.).

Background The detection of in-stent restenosis (ISR) with coronary CT angiography (CCTA) is challenging, but CT perfusion (CTP) has demonstrated improved diagnostic accuracy over CCTA in patients with stents. However, there are limited data on the performance of dynamic CTP, which allows noninvasive adjudication of regional myocardial blood flow. Purpose To compare the diagnostic performance of regadenoson-stress dynamic CTP with that of CCTA, using fractional flow reserve (FFR) and the index of microvascular resistance (IMR) as reference standards for epicardial coronary circulation and coronary microcirculation, respectively.

View Article and Find Full Text PDF

Aims: Photon-counting detector computed tomography (PCD-CT), which allows the exclusion of electronic noise, shows promise for significant dose reduction in coronary CT angiography (CCTA). This study aimed to assess the radiation dose and image quality of CCTA using PCD-CT, combined with high-pitch helical scanning and an ultra-low tube potential of 70 kVp, and investigate the effect of a sharp kernel on image quality and stenosis assessment in such an ultra-low-dose CCTA setting.

Methods And Results: Forty patients (65% male) with stable heart rates and no prior coronary interventions were included.

View Article and Find Full Text PDF

Plasma proteomics improves prediction of coronary plaque progression.

Eur Heart J Cardiovasc Imaging

December 2024

Department of Cardiology, Amsterdam University Medical Centers, Vrije Universiteit Amsterdam, Amsterdam, the Netherlands.

Aims: Coronary computed tomography angiography (CCTA) offers detailed imaging of plaque burden and composition, with plaque progression being a key determinant of future cardiovascular events. As repeated CCTA scans are burdensome and costly, there is a need for non-invasive identification of plaque progression. This study evaluated whether combining proteomics with traditional risk factors can detect patients at risk for accelerated plaque progression.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!