Objective: To investigate whether four-screw fixation in rhombic configuration could improve the clinical outcomes and decrease the complication rate compared with three-screw fixation in inverted triangle configuration in elderly patients with nondisplaced femoral neck fractures.

Method: From January 2018 to January 2019, 91 elderly patients with nondisplaced femoral neck fractures who were treated with a cannulated screw system were reviewed retrospectively. The inverted triangle configuration was applied in 51 patients and rhombic configuration in 40 patients. The demographic and perioperative information of the patients were extracted from medical records and surgical records. Variables including incision size, surgical blood loss, surgical time, fluoroscopy time, hospital stays, fracture union time, postoperative visual analogue scale (VAS) scores, and complications were compared between the two groups. Also, Harris hip score at the final follow-up was used to evaluate the functional outcomes.

Results: All patients were followed up from 24 to 36 months, with an average of 29.75 months. The average age of patients was 72.37 ± 7.16 years. No significant differences were found between the two groups with regard to patients' age, gender, affected side, Garden classification, Pauwels classification and comminution of posterior wall (P > 0.05). We found shorter incision size (P < 0.001), less blood loss (P = 0.020), less surgical time (P = 0.026), and shorter fluoroscopy time (P < 0.001) in inverted triangle configuration group. However, shorter hospital stays (P = 0.001) and fracture union time (P = 0.002) were found in the rhombic configuration group. The VAS scores were lower in the rhombic configuration group at the first (P < 0.001) and third months (P = 0.010), but no significant difference was found at the sixth month (P = 0.075). Meanwhile, the total complication rate was relatively lower in the rhombic configuration group compared to the inverted triangle configuration group (P = 0.041). Harris hip score presented no significant difference between the two groups at final follow-up (P = 0.078). No wound infection or cortical perforation occurred in either group.

Conclusion: Four-screw fixation in rhombic configuration was superior to three-screw fixation in inverted triangle configuration in the treatment of nondisplaced femoral neck fractures in elderly patients in terms of less early postsurgical pain, shorter fracture union time, and lower complication rate.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9002070PMC
http://dx.doi.org/10.1111/os.13223DOI Listing

Publication Analysis

Top Keywords

inverted triangle
12
nondisplaced femoral
12
femoral neck
12
elderly patients
12
neck fractures
8
patients
8
rhombic configuration
8
triangle configuration
8
patients nondisplaced
8
incision size
8

Similar Publications

Previous research indicates that both adults and newborns show enhanced electrophysiological and behavioral responses to schematic face-like configurations (FCs-three dots composing a downward-pointing triangle), as compared to the inverted configurations (ICs). Even fetuses, when exposed to light stimuli projected through the uterine wall, preferentially orient their heads toward FCs rather than ICs. However, when this effect emerges along the third trimester of pregnancy and in relation to the maturation of which brain structures is still unknown.

View Article and Find Full Text PDF

Cardiac compression is the most crucial component of successful cardiopulmonary resuscitation (CPR). However, CPR procedure poses a risk of complications, even when CPR providers perform cardiac compressions as recommended. Reports indicate that solid organ injuries, including liver injuries, occur with an incidence of about 0.

View Article and Find Full Text PDF

In the evolving digital economy, digital transformation has emerged as an important strategic choice for enterprises. Their comprehensive and innovative characteristics have instigated a paradigm shift in enterprise governance ideologies and models. However, this transformation has also introduced heightened demands and challenges to enterprise governance mechanisms during the transitional phase.

View Article and Find Full Text PDF

The process in the inverted hierarchy scenario of the 2HDM type-I at the LHC.

Eur Phys J C Part Fields

November 2024

School of Physics and Astronomy, University of Southampton, Highfield, Southampton, SO17 1BJ UK.

While searching at the Large Hadron Collider (LHC) for the production and decay of the CP-odd scalar ( ) in the 2-Higgs-Doublet Model (2HDM) with Natural Flavour Conservation (NFC) via the channels (through one-loop triangle diagrams) and (with GeV or GeV, with off-shell), respectively, a factorisation of the two processes is normally performed, with the state being on-shell. While this approach is gauge-invariant, it is not capturing the presence of either of the following two channels: (through one-loop triangle diagrams) or (through one-loop box diagrams). As the resolution of the mass cannot be infinitely precise, we affirm that all such contributions should be computed simultaneously, whichever the ( ) decay(splitting) products, thereby including all possible interferences amongst themselves.

View Article and Find Full Text PDF
Article Synopsis
  • Storks use a cooling method called urohidrosis, where they wet their legs with excrement, and also spread their wings to regulate body temperature during hot weather.
  • A study was conducted on Painted Storks in Delhi to observe these behaviors using videography, revealing that temperature and humidity impact their cooling techniques.
  • Male storks engaged in more urohidrosis and wing-spreading than females, with these behaviors peaking during the hottest parts of the day and early in the nesting season, tapering off as temperatures dropped later in the season.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!