Portable fully automated oral fluid extraction device for illegal drugs.

Talanta

Tallinn University of Technology, School of Science, Department of Chemistry and Biotechnology, Akadeemia tee 15, 12618, Tallinn, Estonia. Electronic address:

Published: June 2022

Currently used methods for in-field determination of illegal drugs involve various test kits based mainly on the immunoassay technique, where the presence of a compound of interest is assessed by antibody-antigen reaction and manifested by observable color change. Despite being accepted and widely used by police forces to test the presence of illegal drugs in a suspect person, these tests often suffer from unreliable results (high level of false-positive and/or false-negative) due to the cross-reactivity and difficulties with quantification. Therefore, we have developed a portable capillary electrophoresis instrument to determine illegal drugs in oral fluid collected from a suspected person. However, this drug analyzer has still required manual sample preparation. Therefore, this research aimed to develop, test, and validate a fully automated sample pretreatment (purification, extraction, pre-concentration) prototype compatible with the capillary electrophoresis drug of abuse analyzer and suitable for confirmatory analysis by mass spectrometry. The cotton swab from Salivette® oral fluid collector was examined and integrated into the fully automated extractor prototype. The recoveries for the automated extractor were between 18 and 20%, with repeatabilities within 5-11% for 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxy-N-ethylamphetamine (MDEA), cocaine (COC), and cocaethylene (COET). The developed extraction device was easy to use even for unskilled persons, required minimal liquid handling, and was applicable to use in field conditions.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2022.123389DOI Listing

Publication Analysis

Top Keywords

illegal drugs
16
fully automated
12
oral fluid
12
extraction device
8
capillary electrophoresis
8
automated extractor
8
portable fully
4
automated
4
automated oral
4
fluid extraction
4

Similar Publications

Simultaneous measurement of fentanyl, fentanyl analogues and other drugs of abuse by multiplex bead assay.

Toxicol Mech Methods

January 2025

Centers for Disease Control and Prevention, Division of Science Integration, Risk Evaluation Branch, National Institute for Occupational Safety and Health, Cincinnati, OH, USA.

Quantification of illicit drugs and controlled substances, in urine or as surface contamination, is often performed using expensive analytical techniques such as liquid chromatography with tandem mass spectrometry (LC-MS/MS). A time and cost-effective semi-quantitative surface-wipe and urine screening multiplex immunoassay for fentanyl and its analogues was developed in this investigation. We previously created a surface wipe multiplex immunoassay for methamphetamine, caffeine, cocaine, tetrahy-drocannabinol (THC) and oxycodone.

View Article and Find Full Text PDF

In 2019, intranasal esketamine gained approval as a promising therapy for those individuals grappling with treatment-resistant depression. Both clinical trials and real-world studies have underscored its efficacy in alleviating and remitting depressive symptoms, with sustained benefits observed for nearly 4.5 years.

View Article and Find Full Text PDF

Work-related stress has been well-examined among physicians, but little is known about how it might affect drug use or healthcare workers in lower-wage occupations characterized by high job demands and low occupational autonomy (e.g., medical assistants, nursing assistants).

View Article and Find Full Text PDF

Effect of UV exposure on DNA deposited on drug capsules.

Forensic Sci Int

January 2025

College of Science and Engineering, Flinders University, Bedford Park, South Australia 5042, Australia.

Illicit drugs are often made in less-than-sterile environments and can be stored in ways which can be detrimental to any DNA present, such as whether they are exposed to UV radiation. Previously, analysis of how exposure to UV impacted DNA for forensic applications has been in controlled laboratory conditions isolating a single component of UV radiation and often on DNA-rich samples such as bloodstains or saliva. To evaluate DNA persistence in more realistic conditions, capsules, such as those used to distribute controlled substances, were manually made and then packed into ziplock bags.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!