A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Controllable Fabrication of Small-Size Holding Pipets for the Nondestructive Manipulation of Suspended Living Single Cells. | LitMetric

Controllable Fabrication of Small-Size Holding Pipets for the Nondestructive Manipulation of Suspended Living Single Cells.

Anal Chem

Center of Excellence for Environmental Safety and Biological Effects, Beijing Key Laboratory for Green Catalysis and Separation, Department of Chemistry and Biology, Beijing University of Technology, Beijing 100124, China.

Published: March 2022

The capture and manipulation of single cells are an important premise and basis for intracellular delivery, which provides abundant molecular and omics information for biomedical development. However, for intracellular delivery of cargos into/from small-size suspended living single cells, the capture methods are limited by the lack of small-size holding pipets, poor cell activity, and the low spatial accuracy of intracellular delivery. To solve these problems, a method for the controllable fabrication of small-size holding pipets was proposed. A simple, homemade microforge instrument including an imaging device was built to cut and melt the glass capillary tip by controlling the heat production of a nichrome wire. The controllable fabrication of small-size holding pipets was realized by observing the fabrication process in real time. Combined with an electroosmotic drive system and a micromanipulation system with high spatial resolution, the holding pipet achieved the active capture, movement, and sampling of suspended living single cells. Moreover, solid-phase microextraction was performed on captured single pheochromocytoma cells, and the extracted dopamine was successfully detected using an electrochemical method. The homemade microforge instrument overcame the limitations of traditional microforges, resulting in holding pipets that were sufficiently small for small-size suspended single living cells (5-30 μm). This proactive capture method overcame the shortcomings of existing methods to achieve the multiangle, high-precision manipulation of single cells, thereby allowing the intracellular delivery of small-size single cells in suspension with high spatiotemporal resolution.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.analchem.2c00418DOI Listing

Publication Analysis

Top Keywords

single cells
24
holding pipets
20
small-size holding
16
intracellular delivery
16
controllable fabrication
12
fabrication small-size
12
suspended living
12
living single
12
single
8
cells
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!