Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To determine the characteristics of the laterality of the ocular microcirculation parameters obtained from laser speckle flowgraphy (LSFG) in the optic nerve head (ONH).
Subjects And Methods: We reanalyzed a total of 240 healthy subjects (169 men, 71 women) who had participated in a medical checkup program. We analyzed the average mean blur rate (MBR), maximum MBR (Max-MBR), minimum MBR (Min-MBR), and area ratio of the blood stream (ARBS). As the pulse waveform parameters, we also calculated the skew, blowout score (BOS), blowout time (BOT), rising rate, falling rate, flow acceleration index (FAI), acceleration time index (ATI), resistivity index (RI), and beat strength over MBR (BOM). All parameters were compared between left and right eyes.
Results: MBR-average, MBR-Max, MBR-Min, ARBS, skew, BOT, rising rate, falling rate, FAI, ATI, and ARBS did not differ significantly between the right and left eyes. The BOS in the right eyes was significantly lower than that of the left eyes, and the RI and BS in the right eyes were significantly higher than those of the left eyes. Similarly, for the whole of the ONH, the BOS in the tissue area (Tissue) and in the vessel area (Vessel) of the right eyes were significantly lower than those of the left eyes, and RI-Tissue, RI-Vessel, BOM-Tissue, and BOM-Vessel in the right eyes were significantly higher than those of the left eyes.
Conclusion: By using LSFG, we observed laterality of the BOS, RI, and BOM, all of which are pulse wave form parameters in the ONH.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00417-022-05631-8 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!