A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Portable ultrasound assessment of jugular venous pressure is an accurate method for estimating volaemic status in patients with cardiac disease. | LitMetric

Purpose: The objective of this study was to determine whether ultrasound-measured jugular venous pressure (U-JVP) could accurately estimate central venous pressure (CVP).

Methods: This prospective, diagnostic, single-centre study was performed at the Cardiac Intensive Care Unit of the Northern General Hospital, Sheffield, UK. Post-cardiac surgery patients were recruited from January to May 2019. The investigators were blinded to the central venous pressure when measuring the jugular venous pressure. U-JVP and direct CVP were measured simultaneously. Measurements were taken whilst the patient was ventilated and then repeated when the patient was extubated, providing non-ventilated readings.

Results: One-hundred and fourteen consecutive participants with a male predominance of 71% and mean age of 65 ± 12 years were included in the analysis. Bland-Altman plots revealed that U-JVP marginally overestimated CVP by 0.91 mmHg (95% limits of agreement were -2.936 to 4.754) in ventilated patients and by 0.11 mmHg (95% limits of agreement between -2.481 and 2.695) in non-ventilated patients. Reasonable sensitivity and specificity of ultrasound-measured jugular venous pressure was achieved for low and high central venous pressure in both ventilated and non-ventilated patients.

Conclusion: U-JVP accurately estimates cardiac filling pressure and fluid status in patients after cardiac surgery, irrespective of their ventilatory status. Jugular venous pressure measurement by insonation is a reliable technique that can be taught to medical students and other health professionals to non-invasively estimate central venous pressure and may be useful for assessment of volaemic status in patients with heart failure.

Trial Registration: ClinicalTrials.gov public (identifier NCT03815188).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9705668PMC
http://dx.doi.org/10.1007/s40477-022-00654-7DOI Listing

Publication Analysis

Top Keywords

venous pressure
36
jugular venous
20
central venous
16
status patients
12
pressure
10
venous
9
volaemic status
8
patients cardiac
8
ultrasound-measured jugular
8
pressure u-jvp
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!