Molecular methods are necessary to detect low-density malaria infections. The purpose of this study was to assess the diagnostic performance of six malachite-green loop-mediated amplification method (MG-LAMP) assays (MG-LAMP-Pf, MG-LAMP-Pv, MG-LAMP-Po, MG-LAMP-Pm, MG-LAMP-Pk, and MG-LAMP-Pspp) for the species-specific detection of each human Plasmodium, including P. knowlesi, and the Plasmodium genus compared with the nested-multiplex malaria polymerase chain reaction (NM-PCR), using 161 malaria-positive and 274 malaria-negative samples. MG-LAMP-Pspp assay detected the five human Plasmodium species and each species-specific MG-LAMP assay detected only its corresponding species. Sensitivity, specificity, and predictive values of MG-LAMP assays, compared with NM-PCR, were > 90%, except in the case of the MG-LAMP-Pm assay, which dropped to 47%. Limit of detection for MG-LAMP-Pspp assay ranged from 0.1 parasites/µL for P. falciparum to 16.9 parasites/µL for P. malariae samples, and it was similar for the rest of MG-LAMP assays except for the MG-LAMP-Pm assay. Turnaround time was estimated to be 2 hours and 35 minutes for one MG-LAMP assay and 4 hours and 15 minutes if all species-specific MG-LAMP is set up, whereas for the NM-PCR, turnaround time was ∼6 hours and 15 minutes. Costs per determination ranged from 1 to 6 euros for MG-LAMP assays and 5 euros for NM-PCR. Therefore, MG-LAMP assays appear to have good concordance compared with the reference method, except for the MG-LAMP-Pm assay. They can detect low parasitemia and identify malaria species, with lower costs and shorter time to obtain results, and they are suitable tools to be used in endemic and non-endemic countries for malaria detection.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9128691 | PMC |
http://dx.doi.org/10.4269/ajtmh.21-1151 | DOI Listing |
Exp Parasitol
August 2022
Department of Parasitology, Faculty of Medicine, Universiti Malaya, 50603, Kuala Lumpur, Malaysia. Electronic address:
In order to ascertain the results of the LAMP technique, different end-point detection methods can be employed. However, these methods require sophisticated equipment. To simplify current end-point detection methods for the diagnosis of malaria, we propose the incorporation of colorimetric dyes: malachite green (MG), phenol red (PR), and xylenol orange (XO) in the LAMP assay.
View Article and Find Full Text PDFAm J Trop Med Hyg
March 2022
Malaria and Emerging Parasitic Diseases Laboratory, National Microbiology Centre, Instituto de Salud Carlos III, Madrid, Spain.
Molecular methods are necessary to detect low-density malaria infections. The purpose of this study was to assess the diagnostic performance of six malachite-green loop-mediated amplification method (MG-LAMP) assays (MG-LAMP-Pf, MG-LAMP-Pv, MG-LAMP-Po, MG-LAMP-Pm, MG-LAMP-Pk, and MG-LAMP-Pspp) for the species-specific detection of each human Plasmodium, including P. knowlesi, and the Plasmodium genus compared with the nested-multiplex malaria polymerase chain reaction (NM-PCR), using 161 malaria-positive and 274 malaria-negative samples.
View Article and Find Full Text PDFPLoS One
November 2021
Department of Parasitology, U.S. Naval Medical Research Unit N°6 (NAMRU-6), Lima, Peru.
Malaria elimination efforts in Peru have dramatically reduced the incidence of cases in the Amazon Basin. To achieve the elimination, the detection of asymptomatic and submicroscopic carriers becomes a priority. Therefore, efforts should focus on tests sensitive enough to detect low-density parasitemia, deployable to resource-limited areas and affordable for large screening purposes.
View Article and Find Full Text PDFMalar J
September 2020
Kenya Medical Research Institute, Centre for Global Health Research, P. O. Box 1578-40100, Kisumu, Kenya.
Background: Prompt diagnosis and effective malaria treatment is a key strategy in malaria control. However, the recommended diagnostic methods, microscopy and rapid diagnostic tests (RDTs), are not supported by robust quality assurance systems in endemic areas. This study compared the performance of routine RDTs and smear microscopy with a simple molecular-based colorimetric loop-mediated isothermal amplification (LAMP) at two different levels of the health care system in a malaria-endemic area of western Kenya.
View Article and Find Full Text PDFPLoS One
August 2020
Department of Parasitology, U.S. Naval Medical Research Unit 6 (NAMRU-6), Lima, Peru.
The current context of malaria elimination requires urgent development and implementation of highly sensitive and specific methods for prompt detection and treatment of malaria parasites. Such methods should overcome current delays in diagnosis, allow the detection of low-density infections and address the difficulties in accessing remote endemic communities. In this study, we assessed the performance of the RealAmp and malachite-green loop mediated isothermal amplification (MG-LAMP) methodologies, using microscopy and conventional nested-PCR as reference techniques.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!