COVID-19 pandemic has affected clean energy labor market. Using real-time job vacancy data, this study analyzes the impacts of the pandemic on the U.S. clean energy labor market in 2020, including biomass, energy efficiency (EE), electric vehicle (EV), power/microgrid, solar, and wind industries. This study identifies how COVID-health factors and public health interventions influence clean energy job availability during the early COVID pandemic. Overall, California had the most energy jobs and experienced a significant decrease in April 2020. EV and solar had the highest percentages of job vacancies during the pandemic in general. Still, lockdowns had the most severe influence on EE and wind jobs. Stay-at-home orders negatively affected clean energy job vacancies in biomass, EV, power/microgrid, and wind. Social-gathering restrictions, however, did not have much influence. Increased COVID tests at the state level had the strongest and most positive influence on clean energy job postings, indicating the importance of a state's ability to manage public health infrastructure or crisis issues. COVID hospitalizations negatively influenced the job vacancies in biomass and wind but did not affect the other four sectors; conversely, as COVID death numbers increased, the number of jobs in biomass, EV, power grid, solar, and wind decreased, but not in EE jobs.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8913264PMC
http://dx.doi.org/10.1016/j.enpol.2022.112880DOI Listing

Publication Analysis

Top Keywords

clean energy
24
energy labor
12
public health
12
energy job
12
job vacancies
12
energy
8
health interventions
8
covid-health factors
8
pandemic clean
8
labor market
8

Similar Publications

Designing efficient Ruthenium-based catalysts as practical anodes is of critical importance in proton exchange membrane water electrolysis. Here, we develop a self-assembly technique to synthesize 1 nm-thick rutile-structured high-entropy oxides (RuIrFeCoCrO) from naked metal ions assembly and oxidation at air-molten salt interface. The RuIrFeCoCrO requires an overpotential of 185 mV at 10 m A cm and maintains the high activity for over 1000 h in an acidic electrolyte via the adsorption evolution mechanism.

View Article and Find Full Text PDF

Passive Radiant Cooling and Heating are green and sustainable methods of radiant heat management without consuming additional energy. However, the absorption of sunlight and poor insulation of materials can reduce radiative cooling and also affect radiative heating performance. Herein, we have constructed porous hierarchical dual-mode silk nanofibrous aerogel (SNF) films with high mechanical toughness and stability using silk nanofibers/GO.

View Article and Find Full Text PDF

Toxic and carcinogenic compounds, such as synthetic dyes and polyphenols, were widely employed and released as pollutants in a variety of industries, including textiles, food, and cosmetics. Biological oxidation process that used oxidizing enzymes to breakdown pollutant compounds were environmentally favorable. However, due to the cell toxicity of metal ions supplements used for the biosynthesis of oxidizing enzymes like laccase, their efficient application for biological degradation is limited.

View Article and Find Full Text PDF

Pollution profiles, pathogenicity, and toxicity of bioaerosols in the atmospheric environment of urban general hospital in China.

Environ Pollut

January 2025

Guangdong Key Laboratory of Environmental Catalysis and Health Risk Control, School of Environmental Science and Engineering, Institute of Environmental Health and Pollution Control, Guangdong University of Technology, Guangzhou 510006, China.

Airborne microorganisms in hospitals present significant health risks to both patients and employees. However, their pollution profiles and associated hazards in different hospital areas remained largely unknown during the extensive use of masks and disinfectants. This study investigated the characteristics of bioaerosols in an urban general hospital during the COVID-19 pandemic and found that airborne bacteria and fungi concentrations range from 87±35 to 1037±275 CFU/m and 21±15 to 561±132 CFU/m, respectively, with the outpatient clinic and internal medicine ward showing the highest levels.

View Article and Find Full Text PDF

The synergies of air quality monitoring program: Information disclosure and pollution control.

J Environ Manage

January 2025

Chongqing Environmental Consulting Co., Ltd., CISDI Group Co., Ltd., Chongqing, China. Electronic address:

To deal with the increasingly severe climate crisis and environmental pollution, China launched a nationwide real-time air quality monitoring program in three batches, a milestone moment in its environmental governance history. Using the time-varying difference-in-differences model, this study explores the synergies of this program across 284 cities from 2009 to 2019. The findings are as follows: (1) With environmental information disclosed, the national air quality monitoring program can reduce the outdoor fine particulate matter concentration by an overall effect of 3.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!