Objectives: The aim of the study was to evaluate the hearing status of operators of low-frequency ultrasonic devices compared to employees exposed to audible noise at a similar A-weighted sound pressure level (SPL) but without ultrasonic components.

Material And Methods: Standard pure-tone audiometry, extended high-frequency audiometry (EHFA), transient-evoked otoacoustic emissions (TEOAE), and distortion-product otoacoustic emissions (DPOAE), as well as questionnaire surveys were conducted among 148 subjects, aged 43.1±10.8 years, working as ultrasonic device operators for 18.7±10.6 years. Their exposure to noise within the ultrasonic and audible frequency range was also evaluated. The control group comprised 168 workers, adjusted according to gender, age (±2 years), tenure (±2 years), and the 8-hour daily noise exposure level (L) of ±2 dB.

Results: The ultrasonic device operators and the control group were exposed to audible noise at L of 80.8±3.9 dB and 79.1±3.4, respectively. The Polish maximum admissible intensity (MAI) values for audible noise were exceeded in 16.8% of the ultrasonic device operators, while 91.2% of them were exposed to ultrasonic noise at SPL>MAI values. There were no significant differences between the groups in terms of the hearing threshold levels (HTLs) up to 3 kHz, while the ultrasonic device operators exhibited significantly higher (worse) HTLs, as compared to the control group, in the range of 4-14 kHz. The results of the DPOAE and TEOAE testing also indicated worse hearing among the ultrasonic device operators. However, the differences between the groups were more pronounced in the case of EHFA and DPOAEs.

Conclusions: The outcomes of all hearing tests consistently indicated worse hearing among the ultrasonic device operators as compared to the control group. Both EHFA and DPOAE seem to be useful tools for recognizing early signs of hearing loss among ultrasonic device operators. nt J Occup Med Environ Health. 2022;35(3):309-25.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10464771PMC
http://dx.doi.org/10.13075/ijomeh.1896.01816DOI Listing

Publication Analysis

Top Keywords

ultrasonic device
28
device operators
28
control group
16
ultrasonic
12
audible noise
12
hearing status
8
exposed ultrasonic
8
ultrasonic noise
8
operators
8
exposed audible
8

Similar Publications

Dental ultrasonic scalers are commonly employed in periodontal treatment; however, their ability to roughen tooth surfaces is a worry since roughness may increase plaque production, a key cause of periodontal disease. This research studied the influence of a piezoelectric ultrasonic scaler on the roughness of two distinct flowable composite filling materials. To do this, 10 disc-shaped samples were generated from each of the two flowable composite materials.

View Article and Find Full Text PDF

One area of technological advancement has been the shift from stainless steel hand tools to nickel-titanium (Ni-Ti) rotary tools. This paper aims to perform an in vitro comparative study to evaluate the efficacy of five endodontic manual and rotary instruments such as Kerr files, Orodeka Plex V, ProTaper Flydent NiTi super files, and ProTaper Flydent NiTi super files in combination with an ultrasonic endodontic E3D Diamantata EMS scaler used for root canal shaping. The following aspects were highlighted: effective removal of smear layer (SL) from the dentinal tubules in the coronal 1/3, middle 1/3, and apical 1/3 of the root canal, appearance of cracks in the dentinal walls by SEM analysis, and highlighting of dentin mineral content and remnant debris by EDX analysis.

View Article and Find Full Text PDF

Background: Transcatheter valve-in-valve replacement (TMViVR) is an alternative option for patients with bioprosthetic valve failure (BVF) who are at high surgical risk. Although infective endocarditis (IE) after transcatheter mitral valve-in-valve replacement is unusual, it is associated with significantly high mortality.

Case Presentation: An 81-year-old male patient was admitted with intermittent thoracic tightness, chest pain persisting for 3 years, and shortness of breath with nausea for 1 week.

View Article and Find Full Text PDF

Background: Early literature on the Woven EndoBridge (WEB) device reported 80-90% adequate aneurysm occlusion but low complete occlusion (40-55%). It is uncertain whether residual or recurrent aneurysms require re-treatment to prevent future rupture.

Objective: To systematically review the literature to meta-analyze occlusion and complication rates after re-treatment of these aneurysms.

View Article and Find Full Text PDF

Flexible and Durable Conducting Fabric Electrodes for Next-Generation Wearable Supercapacitors.

ACS Appl Mater Interfaces

January 2025

Department of Physics, School of Electrical and Electronics Engineering, SASTRA Deemed to be University, Thanjavur 613 401, Tamil Nadu, India.

This study presents the fabrication of highly conducting Au fabric electrodes using a layer-by-layer (LBL) approach and its application toward energy storage. Through the ligand-exchange mechanism, the alternating layers of tris(2-aminoethyl)amine (TREN) and gold nanoparticles (Au NPs) encapsulated with tetraoctylammonium bromide (TOABr) ligands (Au-TOABr) were deposited onto the fabric to achieve a highly conducting Au fabric (0.12 Ω/□) at room temperature in just two LBL cycles.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!