A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Analysis of Denosumab by a Validated CZE Method and Determination of Sialic Acids by the RP-HPLC Method. | LitMetric

A capillary zone electrophoresis (CZE) method was developed and validated to quantitate the monoclonal antibody denosumab (DmAb) and its charge variants in pharmaceutical products, demonstrating excellent precision, linearity and accuracy. Separations were obtained with migration times of 11.3 min for DmAb and the calibration curve was linear in the range of 0.95-20 mg/mL. The analytical comparability of seven batches of Prolia® showed mean differences of the estimated content/potencies of 1.87% lower, and 0.84 and 1.21% higher compared with the size-exclusion and reversed-phase liquid chromatography (SE-HPLC and RP-HPLC) methods and the osteoclast antiproliferative bioassay, respectively, with non-significant differences (P > 0.05). An RP-HPLC method with fluorescence detection (RP-HPLC-F), performed on a Kinetex® EVO C18 column (5 μm, 100 Å, 250 mm × 4.6 mm), was optimized to determine the levels of sialic acids of DmAb biomolecules, giving mean concentrations of 0.16 and 0.17 μg N-acetylneuraminic acid/mg DmAb for Prolia® and Xgeva® pharmaceutical products, respectively. The results demonstrated the capability of each one of the methods, and their use in combination constitutes a strategy to monitor instability, thereby assuring the quality and the batch-to-batch consistency of the biotechnology-derived medicine.

Download full-text PDF

Source
http://dx.doi.org/10.1093/chromsci/bmac019DOI Listing

Publication Analysis

Top Keywords

cze method
8
sialic acids
8
rp-hplc method
8
pharmaceutical products
8
analysis denosumab
4
denosumab validated
4
validated cze
4
method
4
method determination
4
determination sialic
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!