A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparative Effectiveness between Expanded Hemodialysis (Hemodialysis Using a Medium Cut-Off Dialyzer) and Mixed-Dilution Online Hemodiafiltration Using a High-Flux Dialyzer in Removing Middle-Molecule Uremic Toxins. | LitMetric

Introduction: Expanded hemodialysis (HD using a medium cut-off dialyzer [HD + MCO]) provides comparable or better removal of various uremic toxins, particularly large middle-molecule uremic toxins, than post-dilution online hemodiafiltration (olHDF). Uremic toxin-removing effectiveness between HD + MCO and mixed-dilution olHDF, one of the currently most efficient olHDF modalities, has not been assessed.

Method: This randomized controlled trial was conducted in 14 prevalent thrice-a-week HD patients with blood flow rate above 400 mL/min. The patients were randomized into two sequences of 2-week treatment periods of HD + MCO and later mixed-dilution olHDF or vice versa. The reduction ratio (RR) values of small-molecule as well as middle-molecule uremic toxins and protein-bound uremic toxins were measured at baseline and at the end of the treatment.

Results: When compared with mixed-dilution olHDF, HD + MCO provided slightly lower β2M RR, but the value was still higher than 75%; showed similar κFLC RR, IS RR, and URR; and yielded significantly higher RR values of α1M (p < 0.001) and λFLC (p < 0.001). Despite higher albumin loss in HD + MCO, the serum albumin levels at the end of the study were comparable between both groups.

Conclusion: Expanded HD (HD + MCO) provided similar effectiveness in removing various uremic toxins and could exhibit greater removal of large middle-molecule uremic toxins, such as α1M and λFLC. Expanded HD can be used as an effective alternative option for mixed-dilution olHDF.

Download full-text PDF

Source
http://dx.doi.org/10.1159/000521886DOI Listing

Publication Analysis

Top Keywords

uremic toxins
28
middle-molecule uremic
16
mixed-dilution olhdf
16
expanded hemodialysis
8
hemodialysis medium
8
medium cut-off
8
cut-off dialyzer
8
online hemodiafiltration
8
uremic
8
large middle-molecule
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!