Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A comparative study on the uptake of Eu(III) and Am(III) was carried out using four extraction chromatography (XC) resins impregnated with constant weight of the tetra-n-pentyl diglycolamide (TPDGA) ligands, viz. tetra-n-hexyl diglycolamide (THDGA), tetra-n-octyl diglycolamide (TODGA) and tetra-n-decyl diglycolamide (TDDGA) along with Cmim·NTf, a room temperature ionic liquid (RTIL), from nitric acid feed solutions. The uptake of Eu(III) was higher than that of Am(III) while the uptake trend with the four XC resins followed the order: TPDGA > THDGA > TODGA > TDDGA, which was opposite to the alkyl chain length attached to the DGA extractant. When constant moles of the extractants were used, the observed trend was TODGA > THDGA > TDDGA > TPDGA. Also, for all the four XC resins, the uptake of both Eu(III) and Am(III) ions increased with increasing nitric acid concentration. The uptake data with all the four resins were fitted into different kinetic and isotherm models which conformed to a pseudo-second order kinetics and Langmuir monolayer sorption isotherm. Furthermore, columns were prepared with these XC resins and were used to obtain breakthrough profiles using a feed solution containing 0.55 g/L Eu(III) in 3 M HNO. Subsequently, the elution of the loaded metal ion from the column was accomplished with a strippant solution containing 1 M guanidine carbonate + 0.05 M EDTA in distilled water. Elution profiles for all the four resins showed sharp peaks with almost no tailing.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.chroma.2022.462928 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!