Correction of Bowtie filter induced scatter signals based on air scan data and object scan data.

Biomed Phys Eng Express

Siemens Shanghai Medical Equipment Ltd, 278 Zhouzhu Rd., Pudong District, Shanghai 201318, People's Republic of China.

Published: June 2022

In a cone beam CT system, a bowtie filter brings in additional scatter signals with respect to object induced scatter signals, which can degrade image quality and sometimes result in artifacts. This work aims to improve the image quality of CT scans by analyzing the contribution of bowtie filter induced scatter signals and removing them from projection data. Air calibration is a very useful preprocessing step to eliminate the response variations of detector pixels. Bowtie filter induced scattered x-ray signals of air scans are recorded in air calibration tables and therefore considered as a part of primary signals. However, scattered X-rays behave differently in scanned objects compared to primary x-rays. The difference should be corrected to eliminate the impact of bowtie filter induced scatter signals. A kernel based correction algorithm based on air scan data, named bowtie filter scatter correction algorithm, is applied to estimate and to eliminate the bowtie filter induced scatter signals in object scans. The scatter signals of air scans can be measured with air scans or retrieved from air calibration tables of a CT system, and can be used as input of the correction algorithm to estimate the change of scatter signals caused by the scanned objects in the scan field. Based on the assumption that the scatter signals in the projection data scanned with narrow collimation can be neglected, the difference signals between narrow and broad collimations can be used to estimate bowtie filter induced scatter signals for air scans with the correction of extra-focal radiations (EFRs). The calculated bowtie filter induced scatter signals have been compared with the results of Monte Carlo simulations, and the parameters of correction algorithm have been determined by fitting the measured scatter signal curves of phantom scans with calculated curves. Projection data have been reconstructed using Filtered BackProjection (FBP) method with and without bowtie filter correction to check whether the image quality is improved. Scatter signals can be well approximated with the bowtie filter scatter correction algorithm together with an existing object scatter correction algorithm. After removing the bowtie filter induced scatter signals, the dark bands in reconstructed images in the regions near the edges of scanned objects can be mostly eliminated. The difference signals of air scan data between narrow and broad collimations can be used to estimate the bowtie filter induced scatter for air scans. The proposed bowtie filter scatter correction algorithm using air scan data can be applied to estimate and to remove most of the bowtie filter induced scatter signals in object scans.

Download full-text PDF

Source
http://dx.doi.org/10.1088/2057-1976/ac5d0cDOI Listing

Publication Analysis

Top Keywords

bowtie filter
60
scatter signals
56
filter induced
40
induced scatter
40
correction algorithm
28
scatter
20
scan data
20
air scans
20
signals
18
air scan
16

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!