Objective: The aim of this study was to compare the fracture behavior of cantilever fixed dental prostheses (FDPs) fabricated from 3Y-TZP, 4Y-TZP, or 5Y-TZP zirconia.
Method And Materials: Posterior cantilever FDPs (three groups, each n = 16) were digitally designed and milled. After sintering, eight specimens/group were stored in demineralized water for 72 hours; eight specimens/group were subjected to accelerated aging using chewing simulation with thermal cycling (1,200,000 × 50 N; 2 × 3,000 × 5°C/55°C; H2O, 2 minutes/cycle) and finally stored in demineralized water for 24 hours. The cantilever FDPs were then statically loaded to failure to determine fracture load. Phase transformation towards the monoclinic phase was controlled with x-ray diffractometry.
Results: One failure was identified after accelerated aging in the 5Y-TZP group. Fracture load decreased with increasing yttria content and decreasing bending strength. Accelerated aging using chewing simulation with thermal cycling caused a significant decline in fracture load. All FDPs failed in the area of the prepared tooth and in proximity to the cantilever, where the largest bending moment occurred. The yttria content had no influence on the type of fracture. With increasing yttria content, the relation between deformation and fracture load decreased only slightly. On the surface of FDPs that had been subjected to chewing simulation, no phase transformation towards the monoclinic phase (eg, low temperature degradation) was detected.
Conclusion: Within the limitations of a laboratory study, the data indicate that 3Y-, 4Y-, and 5Y-TZP may be employed as material for the fabrication of permanent posterior cantilever FDPs. However, more data are necessary to finally advocate the application of 5-Y-TZP. (Quintessence Int 2022;53:414-422; doi: 10.3290/j.qi.b2793243).
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3290/j.qi.b2793243 | DOI Listing |
Mil Med
January 2025
Department of Orthopaedic Surgery, Walter Reed National Military Medical Center, Bethesda, MD 20889, USA.
Introduction: As illustrated by the "Walker Dip," there is growing concern regarding the lack of combat casualty care during peacetime. Surgical volume and case complexity are paramount for training and skill sustainment. We sought to quantify the recent orthopedic trauma surgical case load of all military orthopedic surgeons across the Military Health System (MHS).
View Article and Find Full Text PDFSensors (Basel)
December 2024
Department of Industrial Engineering and Management, Shanghai Jiao Tong University, Shanghai 200240, China.
Taking the titanium alloy wing-body connection joint at the rear beam of a certain type of aircraft as the research object, this study analyzed the failure mechanism and verified the structural safety of the wing-body connection joint under actual flight loads. Firstly, this study verified the validity of the loading system and the measuring system in the test system through the pre-test, and the repeatability of the test was analyzed for error to ensure the accuracy of the experimental data. Then, the test piece was subjected to 400,000 random load tests of flight takeoffs and landings, 100,000 Class A load tests, and ground-air-ground load tests, and the test piece fractured under the ground-air-ground load tests.
View Article and Find Full Text PDFMaterials (Basel)
January 2025
Key Laboratory of Testing Technology for Manufacturing Process of Ministry of Education, Southwest University of Science and Technology, Mianyang 621010, China.
Materials (Basel)
December 2024
Department of Theory of Structures and Building Information Modeling (BIM), Faculty of Civil Engineering and Architecture, Kielce University of Technology, Al. Tysiaclecia Panstwa Polskiego 7, 25-314 Kielce, Poland.
The bending stiffness of beams represents a pivotal parameter influencing both the dimensions of the elements during their design and their subsequent utilisation. It is evident that excessive deflections can cause discomfort to users and contribute to further structural degradation. The objective of this study was to enhance the bending stiffness of timber beams by bonding a composite sheet to their external surfaces.
View Article and Find Full Text PDFMaterials (Basel)
December 2024
College of Civil Science and Engineering, Yangzhou University, Yangzhou 225100, China.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!