In pregnant women, anaesthesia-induced hypotension is commonly treated using phenylephrine or noradrenaline, the rationale being to maintain uterine perfusion pressure and thereby uterine blood flow. Evidence for this strategy during general anaesthesia for nonobstetric surgery is absent. To analyse the effects of treating anaesthesia-induced hypotension with noradrenaline on brain development of rabbit foetuses of mothers subjected to general anaesthesia for nonobstetric surgery. We hypothesised that treatment of maternal hypotension would improve foetal outcomes. Randomised controlled laboratory study using 21 pregnant rabbits (does) at 28 days of gestation. Two hours of sevoflurane anaesthesia for a laparotomy without treatment of anaesthesia-induced hypotension (hypotension group) or with maintaining maternal mean arterial pressure above 80% of the awake value using noradrenaline (noradrenaline group). In the control group, does remained untouched. At term, all pups were delivered by caesarean section. One day later, the neurobehaviour of the pups was assessed and brains were harvested. Neuron density in the frontal cortex for the comparison of noradrenaline groups versus hypotension groups was the primary outcome; the neurobehavioural scores and other histological outcomes were secondary outcomes. In the noradrenaline groups and hypotension groups, neuron density in the frontal cortex was similar (1181 ± 162 versus 1189 ± 200 neurons mm-2, P = 0.870). However, significantly less foetal survival, lower sensory scores in neurobehavioural assessment and less proliferation were observed in the noradrenaline group when compared with the hypotension group. Neuron densities in other regions, total cell densities, biometrics and synaptogenesis were not affected. There were no differences between the control group and hypotension group. During general anaesthesia for nonobstetric surgery in rabbits, treatment of anaesthesia-induced hypotension using noradrenaline did not affect neuron densities but was associated with impaired foetal outcomes according to several secondary outcome parameters. Further studies are needed to investigate any clinical relevance and to determine the target blood pressure in pregnant women during general anaesthesia.KEY POINTSIn pregnant women, anaesthesia-induced hypotension is commonly treated using phenylephrine or noradrenaline, with the rationale to maintain uterine perfusion pressure and thereby uterine blood flow.Evidence for this strategy during general anaesthesia for nonobstetric surgery is absent.We investigated the effects of treating anaesthesia-induced hypotension with noradrenaline on the brain development of rabbit foetuses, of mothers subjected to general anaesthesia for nonobstetric surgery.We hypothesised that treatment of maternal hypotension would improve foetal outcomes.Neuron densities were similar but significantly less foetal survival, impaired neurobehaviour and less proliferation were observed after treatment of anaesthesia-induced hypotension with noradrenaline, compared with untreated hypotension.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/EJA.0000000000001681 | DOI Listing |
Br J Anaesth
December 2024
Department of Anaesthesiology, Fujian Medical University Union Hospital, Fuzhou, China. Electronic address:
Clin Pharmacokinet
December 2024
Department of Anesthesia, Hangzhou City Linping District Maternal and Children Care Hospital, Hangzhou, China.
Background And Objective: Reports have suggested the use of intravenous infusion of vasopressors as an approach to prevent spinal anesthesia-induced hypotension (SAIH) in women undergoing cesarean deliveries. However, data on the suitability of this technique for obese people are limited. As such, the current experiment was designed to clarify the dose-response relationship associated with the preventive administration of phenylephrine to avoid SAIH during cesarean delivery in obese parturients under combined spinal-epidural anesthesia.
View Article and Find Full Text PDFBMC Pregnancy Childbirth
November 2024
Department of Anesthesia, Jiaxing University Affiliated Women and Children Hospital, No. 2468 East Zhonghuang Road, Jiaxing city, 314050, China.
Background: Intravenous fluid administration and prophylactic vasopressor infusion are the primary methods for preventing spinal anesthesia-induced hypotension during cesarean delivery. However, evidence regarding the impact of different volumes of crystalloid solution on the phenylephrine infusion dosage for preventing this hypotension remains inconclusive. This study aimed to determine the effect of two IV fluid infusion rates (10 or 20 mL/kg/h) on phenylephrine requirement for preventing spinal anesthesia-induced hypotension.
View Article and Find Full Text PDFBMC Anesthesiol
November 2024
Department of Anesthesiology, East Hospital, Tongji University School of Medicine, Shanghai, 200120, China.
Background: Ciprofol, a novel intravenous general anesthetic with a chemical structure similar to propofol, exhibits significantly enhanced potency. It offers a rapid onset, reduced incidence of injection pain, and has comparable effects on heart rate and blood pressure to propofol. However, clinical data on its use for anesthesia induction in cardiac surgery remain limited.
View Article and Find Full Text PDFSci Rep
November 2024
Department of Human Resources, Shanghai Jiaotong University Affiliated Sixth People's Hospital, 600 Yishan Road, Xuhui District, Shanghai, 200233, China.
The inferior vena cava collapsibility index (IVCCI) has been used to predict fluid responsiveness. This study aimed to evaluate the accuracy of the perioperative IVCCI to predict postinduction hypotension (PIH) under general anaesthesia (GA) combined with lumbar plexus sacral plexus block (LSPB) in elderly patients undergoing hip arthroplasty. A total of forty patients aged over 65 years were recruited for this prospective observational study.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!