A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Reproducibility and postacquisition correction methods for quantitative magnetic resonance imaging of the anterior cruciate ligament (ACL). | LitMetric

Quantitative magnetic resonance imaging has been used to evaluate the structural integrity of knee joint structures. However, variations in acquisition parameters between scanners pose significant challenges. Understanding the effect of small differences in acquisition parameters for quantitative sequences is vital to the validity of cross-institutional studies, and for the harmonization of large, heterogeneous datasets to train machine learning models. The study objective was to assess the reproducibility of T * relaxometry and the constructive interference in steady-state sequence (CISS) across scanners, with minimal hardware-necessitated changes to acquisition parameters. It was hypothesized that there would be no significant differences between scanners in anterior cruciate ligament T * relaxation times and CISS signal intensities (SI). Secondarily, it was hypothesized that differences could be corrected by rescaling the SI distribution to harmonize between scanners. Seven volunteers were scanned on 3T Prisma and Tim Trio scanners (Siemens). Three correction methods were evaluated for T *: inverse echo time scaling, z-scoring, and Nyúl histogram matching. For CISS, scans were normalized to cortical bone, scaled by the background noise ratio, and log-transformed. Before correction, significant mean differences of 6.0 ± 3.2 ms (71.8%; p = 0.02) and 0.49 ± 0.15 units (40.7%; p = 0.02) for T * and CISS across scanners were observed, respectively. After rescaling, T * differences decreased to 2.6 ± 2.7 ms (23.9%; p = 0.03), 1.3 ± 2.5 ms (10.9%; p = 0.13), and 1.27 ± 3.0 ms (19.6%; p = 0.40) for inverse echo time, z-scoring, and Nyúl, respectively, while CISS decreased to 0.01 ± 0.11 units (4.0%; p = 0.87). These findings suggest that small acquisition parameter differences may lead to large changes in T * and SI values that must be reconciled to compare data across magnets.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9463398PMC
http://dx.doi.org/10.1002/jor.25319DOI Listing

Publication Analysis

Top Keywords

acquisition parameters
12
correction methods
8
quantitative magnetic
8
magnetic resonance
8
resonance imaging
8
anterior cruciate
8
cruciate ligament
8
ciss scanners
8
hypothesized differences
8
inverse echo
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!