Background/objective: Central venous pressure (CVP) serves as a surrogate for right atrial pressure, and thus could potentially predict a wider range of heart failure conditions. The purpose of this work is to assess CVP, through an implantable sensor incorporated with a novel anchor design, in the inferior and superior vena cava of an animal model.

Methods: Two animals (Dorset sheep) were implanted with sensors at 3 different locations: inferior vena cava (IVC), superior vena cava (SVC), and pulmonary artery (PA). Two sensors with distinct anchor designs considering anatomical requirements were used. A standard PA sensor (trade name Cordella) was deployed in the PA and SVC, whereas a sensor with a modified cylindrical anchor with various struts was designed to reside in the IVC. Each implant was calibrated against a Millar catheter reference sensor. The ability of the central venous sensors to detect changes in pressure was evaluated by modifying the fluid volume of the animal.

Results: The sensors implanted in both sheep were successful, which provided an opportunity to understand the relationship between PA and CVP via simultaneous readings. The mapping and implantation in the IVC took less than 15 minutes. Multiple readings were taken at each implant location using a hand-held reader device under various conditions. CVP recorded in the IVC (6.49 mm Hg) and SVC (6.14 mm Hg) were nearly the same. PA pressure (13-14 mm Hg) measured was higher than CVP, as expected. The SVC waveforms showed clear beats and respiration. Respiration could be seen in the IVC waveforms, but not all beats were easily distinguishable. Both SVC and IVC readings showed increases in pressure (3.7 and 2.7 mm Hg for SVC and IVC, respectively) after fluid overload was induced via extra saline administration.

Conclusion: In this work, the feasibility of measuring CVP noninvasively was demonstrated. The established ability of wireless PA pressure sensors to enable prevention of decompensation events weeks ahead can now be explored using central venous versions of such sensors.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8890339PMC
http://dx.doi.org/10.1016/j.cvdhj.2020.10.004DOI Listing

Publication Analysis

Top Keywords

central venous
16
vena cava
12
venous pressure
8
superior vena
8
svc ivc
8
pressure
7
ivc
7
cvp
6
sensors
6
svc
6

Similar Publications

Objective: Intermittent pneumatic compression (IPC) is considered the standard of care for preventing venous thromboembolism (VTE) in the hospital setting. However, its widespread adoption after hospitalization has been limited due to its shortcomings in obstruction of venous valves and blood reflux. The objective of this study is to compare the effects of continuous graduated pneumatic compression (CGPC), a new device with a novel mechanism, and IPC on lower hemodynamics and the incidence of VTE in patients undergoing arthroplasty.

View Article and Find Full Text PDF

Background: The optimal imaging modality for selecting the device size in patients with atrial fibrillation undergoing one-stop left atrial appendage occlusion (LAAO) with concomitant pulmonary vein isolation (PVi) remains undefined. We compared preprocedural 3-dimensional computed tomography (3D CT) with intra-procedural transesophageal echocardiography (TEE) and left atrial appendage (LAA) angiography in guiding one-stage PVi and LAAO.

Methods: We measured the LAA ostium diameter using an interactive 3D CT system with a central line-based approach and compared these measurements with those from intra-procedural TEE and angiography, and the actual device size.

View Article and Find Full Text PDF

Plasminogen activator inhibitor-1 (PAI-1) is central to fibrinolysis regulation, and genetic variants such as the 4G/4G genotype predispose individuals to hypercoagulability. This case highlights a 46-year-old female patient presenting with acute mesenteric venous thrombosis, where genetic evaluation revealed homozygosity for the PAI-1 4G/4G polymorphism. Management with unfractionated heparin followed by a transition to direct oral anticoagulants led to clinical resolution.

View Article and Find Full Text PDF

Introduction: In colostomy-related complications, variceal hemorrhage particularly induced by cirrhosis and portal hypertension is seldom encountered. The onset of peristome variceal hemorrhage necessitates swift and effective intervention to prevent potentially life-threatening outcomes such as hemorrhagic shock and recurrent stoma bleeding.

Case Presentation: This report details a case of repeated varicose vein hemorrhage around the stoma in a patient with liver cirrhosis.

View Article and Find Full Text PDF

Introduction: Positive end-expiratory pressure (PEEP) and prone positioning can improve gas exchange by promoting uniform lung aeration. However, elevated ventilation pressures may increase intracranial pressure (ICP) and disrupt cerebral autoregulation. This study investigated the effects of PEEP on ICP and cerebral autoregulation in a porcine model with healthy lungs and normal ICP, comparing prone and supine positions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!