The development of highly durable, stretchable, and steady triboelectric nanogenerators (TENGs) is highly desirable to satisfy the tight requirement of energy demand. Here, we presented a novel integrated polymeric membrane that is designed by PEDOT: PSSa-naphthalene sulfonated polyimide (PPNSP)-EMI.BF Electronic skin (e-skin) for potential TENG applications. The proposed TENG e-skin is fabricated by an interconnected architecture with push-pull ionic electrets that can threshold the transfer of charges through an ion-hopping mechanism for the generation of a higher output voltage (Voc) and currents (Jsc) against an electronegative PTFE film. PPNSP was synthesized from the condensation of naphthalene-tetracarboxylic dianhydride, 2,2'-benzidine sulfonic acid, and 4,4'diaminodiphenyl ether through an addition copolymerization protocol, and PEDOT: PSSa was subsequently deposited using the dip-coating method. Porous networked PPNSP e-skin with continuous ion transport nano-channels is synthesized by introducing simple and strong molecular push-pull interactions via intrinsic ions. In addition, EMI.BF ionic liquid (IL) is doped inside the PPNSP skin to interexchange ions to enhance the potential window for higher output Voc and Iscs. In this article, we investigated the push-pull dynamic interactions between PPNSP-EMI.BF e-skin and PTFE and tolerable output performance. The novel PPNSP- EMI.BF e-skin TENG produced upto 49.1 V and 1.03 µA at 1 Hz, 74 V and 1.45 µA at 2 Hz, 122.3 V and 2.21 µA at 3 Hz and 171 V and 3.6 µA at 4 Hz, and 195 V and 4.43 µA at 5 Hz, respectively. The proposed novel TENG device was shown to be highly flexible, highly durable, commercially viable, and a prospective candidate to produce higher electrical charge outputs at various applied frequencies.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8907315 | PMC |
http://dx.doi.org/10.1038/s41598-021-04555-3 | DOI Listing |
JMIR Form Res
January 2025
Limburg Clinical Research Center/Mobile Health Unit, Faculty of Medicine and Life Sciences, Hasselt University, Hasselt, Belgium.
Background: Consumer-oriented wearable devices (CWDs) such as smartphones and smartwatches have gained prominence for their ability to detect atrial fibrillation (AF) through proprietary algorithms using electrocardiography or photoplethysmography (PPG)-based digital recordings. Despite numerous individual validation studies, a direct comparison of interdevice performance is lacking.
Objective: This study aimed to evaluate and compare the ability of CWDs to distinguish between sinus rhythm and AF.
JMIR Mhealth Uhealth
January 2025
ULR 7369 - URePSSS - Unité de Recherche Pluridisciplinaire Sport Santé Société, Univ. Littoral Côte d'Opale, Univ. Lille, Univ. Artois, 189b, Avenue Maurice Schumann, Centre Universitaire des Darses, Dunkerque, 59375, France, 33 328237357.
Background: Wrist-worn photoplethysmography (PPG) sensors allow for continuous heart rate (HR) measurement without the inconveniences of wearing a chest belt. Although green light PPG technology reduces HR measurement motion artifacts, only a limited number of studies have investigated the reliability and accuracy of wearables in non-laboratory-controlled conditions with actual specific and various physical activity movements.
Objective: The purpose of this study was to (1) assess the reliability and accuracy of the PPG-based HR sensor of the Fitbit Charge 4 (FC4) in ecological conditions and (2) quantify the potential variability caused by the nature of activities.
BMC Musculoskelet Disord
January 2025
Department of Health Sciences, Faculty of Medicine, Lund University, Box 117, Lund, 221 00, Sweden.
Background: Osteoarthritis (OA) often leads to pain and functional limitations, impacting work and daily life. Physical activity (PA) is an important part of the treatment. Wearable activity trackers (WATs) offer a novel approach to promote PA but could also aid in finding a sustainable PA level over time.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Physical Therapy, Faculty of Medicine, Universidad de Chile, Independencia 1027, Independencia, 8380453, Chile.
The characteristics of spontaneous movements in infants are essential for the early detection of neurological pathologies, with the Prechtl method being a widely recognized approach. While the Prechtl method is effective in predicting motor risks, its reliance on the evaluator's expertise limits its scalability, particularly in low-income areas. In such contexts, the use of inertial sensors combined with automated analysis presents a promising accessible alternative; however, more research is necessary to get results comparable to those of the Precht method.
View Article and Find Full Text PDFBiomed Microdevices
January 2025
Department of Electrical and Computer Engineering, Rutgers University, Piscataway, NJ, 08854, USA.
Wearable and implantable biosensors have rapidly entered the fields of health and biomedicine to diagnose diseases and physiological monitoring. The use of wired medical devices causes surgical complications, which can occur when wires break, become infected, generate electrical noise, and are incompatible with implantable applications. In contrast, wireless power transfer is ideal for biosensing applications since it does not necessitate direct connections between measurement tools and sensing systems, enabling remote use of the biosensors.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!