A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Technical Note: A method for determination of titanium dioxide concentration in fecal samples. | LitMetric

Titanium dioxide has been used as a marker for determining diet digestibility indirectly, but some authors have expressed difficulty in measuring TiO2 concentrations in fecal material. We developed an accurate and precise method to determine TiO2 concentrations in equine feces. The method includes dry-ashing samples, digestion with (NH4)2SO4 in concentrated sulfuric acid, followed by the addition of H2O2 to produce a yellow to orange color that can be read spectrophotometrically. Accuracy was tested by spike recovery, and precision was tested by examining the coefficient of variation (CV) between duplicates of 449 individual samples. The method described here was compared with a previously published method by examining CV between duplicates of samples analyzed using both methods and comparing them using a paired t-test. Titanium dioxide spike recovery averaged 106%, and the CV between duplicates averaged 4.0%, with 79% of sample pairs having a CV of <5%. When compared with a previously published method, the method described here had a lower CV between duplicates (P < 0.0001). The method described here provides an accurate and precise quantitative analytical procedure for TiO2 in equine fecal samples.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9030201PMC
http://dx.doi.org/10.1093/jas/skac074DOI Listing

Publication Analysis

Top Keywords

titanium dioxide
12
tio2 concentrations
8
spike recovery
8
method
5
technical note
4
note method
4
method determination
4
determination titanium
4
dioxide concentration
4
concentration fecal
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!