A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The coin rotation test: a reliable and valid test in people with Parkinson's disease. | LitMetric

Purpose: To investigate: (1) the interrater, and test-retest reliability of the coin rotation test (CRT) in people with Parkinson's Disease (PwPD); (2) the minimum detectable change in the CRT; (3) the concurrent and known-groups validity of the CRT; and (4) the cut-off times that best discriminate PwPD from healthy people and functionally dependent PwPD from functionally independent PwPD.

Method: Forty-eight PwPD and 33 healthy people were included. The CRT was administered with the nine-hole peg test, Movement Disorders Society Sponsored Unified Parkinson's Disease Rating Scale, Hoehn and Yahr Scale, Parkinson's Disease Questionnaire-8, and Schwab and England Scale.

Results: The CRT had excellent interrater and test-retest reliability. Minimal detectable changes were 5.96 and 8.23 s for the dominant and non-dominant hand, respectively. The CRT correlated with other outcome measures. Significant differences in the CRT times were found between PwPD and healthy people, and between functionally dependent PwPD and functionally independent PwPD. The cut-off times of 12.66 s on the dominant hand and 15.76 s on the non-dominant best discriminated PwPD from healthy people, while 22.99 s on the dominant hand and 23.48 s on the non-dominant best discriminated functionally dependent PwPD from functionally independent PwPD.

Conclusions: The CRT is a reliable, and clinically available tool for assessing manual dexterity in PwPD.Implications for rehabilitationThe coin rotation test is a reliable, valid, and clinically available tool for assessing manual dexterity in Parkinson's Disease.The minimal detectable changes of the coin rotation test are 5.96 s for dominant hand and 8.23 s for the non-dominant hand, which may useful for clinicians and researchers to detect in any true change in manual dexterity after any intervention.The coin rotation test correlated with Parkinson's Disease-specific measurement tools.The coin rotation test times may detect impaired manual dexterity between people with Parkinson's Disease and healthy people, and between functionally dependent and functionally independent in Parkinson's Disease population.

Download full-text PDF

Source
http://dx.doi.org/10.1080/09638288.2022.2044925DOI Listing

Publication Analysis

Top Keywords

coin rotation
24
rotation test
24
parkinson's disease
24
healthy people
20
pwpd healthy
16
functionally dependent
16
functionally independent
16
manual dexterity
16
people parkinson's
12
people functionally
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!