Quantitative assessment of increase in orbital volume after orbital floor fracture reconstruction using a bioabsorbable implant.

Graefes Arch Clin Exp Ophthalmol

Department of Ophthalmology, Severance Hospital, Institute of Vision Research, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.

Published: September 2022

Purpose: To assess the postoperative changes in the orbital volume and the degree of enophthalmos after orbital floor fracture reconstruction using a bioabsorbable implant and to determine the predictors of postoperative orbital volume change.

Methods: Single-center, retrospective case series of 16 patients who underwent orbital floor fracture reconstruction using a bioabsorbable implant [poly(L-lactic acid)-poly(glycolic acid)/β-tricalcium phosphate; Biobsorb β] were included. Three-dimensional volumetric calculations of orbit were determined using computed tomography scans and the degree of enophthalmos was assessed via Hertel exophthalmometry. Postoperative changes in the orbital volume and the degree of enophthalmos and their correlation were assessed.

Results: The mean volume of fractured orbits immediately after surgery was 22.26 ± 1.98 cm, increasing to 23.67 ± 2.00 cm at 6-month follow-up (p < 0.001); the increased orbital volume was associated with postoperative deformation of the implant. The mean degree of enophthalmos was 0.09 ± 0.27 mm at 1-month follow-up, which increased to 0.66 ± 0.30 mm at 6-month follow-up (p = 0.001). Increase in orbital volume and enophthalmos progression showed a linear correlation (R = 0.682, p = 0.004). Patients with more herniated orbital tissue preoperatively showed increased postoperative orbital volume change (p = 0.015), whereas the size of the fracture area was not predictive of postoperative orbital volume change (p = 0.442).

Conclusion: Increase in orbital volume by deformation of the bioabsorbable implant resulted in progressive enophthalmos during the postoperative follow-up period after orbital floor fracture reconstruction. Thus, careful selection of proper implants before surgery and close postoperative follow-up is needed for an optimal outcome.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00417-022-05610-zDOI Listing

Publication Analysis

Top Keywords

orbital volume
36
orbital floor
16
floor fracture
16
fracture reconstruction
16
bioabsorbable implant
16
degree enophthalmos
16
orbital
14
increase orbital
12
reconstruction bioabsorbable
12
postoperative orbital
12

Similar Publications

Purpose: The optic nerve (ON) is mechanically perturbed by eye movements that shift cerebrospinal fluid (CSF) within its surrounding dural sheath. This study compared changes in ON length and CSF volume within the intraorbital ON sheath caused by eye movements in healthy subjects and patients with optic neuropathies.

Methods: Twenty-one healthy controls were compared with 11 patients having primary open angle glaucoma (POAG) at normal intraocular pressure (IOP), and 11 with chronic non-arteritic anterior ischemic optic neuropathy (NA-AION).

View Article and Find Full Text PDF

Objective: A simple and minimally invasive combined procedure, including transconjunctival orbital fat removal and transcutaneous resected orbital fat injection, was performed based on the anatomical characteristics of the lower eyelids in our young Chinese patients. Our study aimed to investigate the efficacy and safety of this procedure in our study population.

Methods: In our retrospective study, a total of 183 consecutive patients underwent a combination of traditional transconjunctival blepharoplasty and nanofat grafting between February 2020 and June 2024.

View Article and Find Full Text PDF

Patients with Moyamoya disease (MMD) exhibit significant alterations in brain structure and function, but knowledge regarding gray matter networks is limited. The study enrolled 136 MMD patients and 99 healthy controls (HCs). Clinical characteristics and gray matter network topology were analyzed.

View Article and Find Full Text PDF

Purpose: Carotid-cavernous fistulas (CCFs) are treated almost exclusively by endovascular techniques, but the frequency of treatments is limited in smaller centers. We analyzed all CCFs treated in our hospital to determine if high-quality treatment of CCFs can be provided in a medium-volume neurovascular center.

Methods: Retrospective quality-control cohort study.

View Article and Find Full Text PDF

Carbon dioxide capture is a vital approach for mitigating air pollution and global warming. In this context, metal-organic frameworks are promising candidates. Particularly, MIL-88A (M), where the metal nodes (M) are connected to fumarate linkers in its structure, has demonstrated significant potential for CO capture.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!