Statement Of Problem: The clinical efficacy of selective laser melting (SLM) for fabricating removable partial dentures (RPDs) is not well established.

Purpose: The purpose of this clinical study was to compare the performance of SLM-fabricated frameworks with that of those fabricated via traditional lost wax casting.

Material And Methods: A double-blind, randomized, crossover design was used to compare cobalt chromium partial denture frameworks (n=29) fabricated by using SLM or traditional methods. The time taken for adjustments and the clinical fit and stability of the adjusted frameworks were appraised. The accuracy of the frameworks was assessed by measuring the space between the occlusal rest seat and the corresponding rest seat. Statistical comparisons between the 2 frameworks were carried out by using a linear mixed-effect model for repeated measurements (α=.05).

Results: Frameworks fabricated by using both SLM and traditional techniques had an acceptable fit based on subjective clinical evaluation. The overall mean ±standard deviation space between the occlusal rest and rest seat for SLM frameworks (273.7 ±44.5 μm) was comparable with that of traditional frameworks (242.2 ±44.5 μm). The clinical fit adjustment time, 7.76 ±6.43 minutes for SLM and 5.49 ±6.39 minutes for traditionally fabricated frameworks, was statistically similar (P=.067).

Conclusions: Dentures fabricated via SLM and traditional techniques had comparable accuracy of fit and clinical fitting time.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.prosdent.2021.12.021DOI Listing

Publication Analysis

Top Keywords

frameworks fabricated
12
fabricated slm
12
slm traditional
12
rest seat
12
frameworks
10
clinical evaluation
8
removable partial
8
partial denture
8
denture frameworks
8
selective laser
8

Similar Publications

Antimicrobial resistance and impaired bone regeneration are the great challenges in treating infected bone defects. Its recurrent and resistant nature, high incidence rate, long-term hospitalization, and high medical costs have driven the efforts of the scientific community to develop new therapies to improve the situation. Considering the complex microenvironment and persistent mechanisms mediated by resistant bacteria, it is crucial to develop an implant with enhanced osseointegration and sustained and effective infection clearance effects.

View Article and Find Full Text PDF

Evaluation of Retentive Forces in Three Types of Removable Partial Denture Framework Materials: An In Vitro Study.

Cureus

December 2024

Dentistry, Kurdistan Higher Council of Medical Specialties, Erbil, IRQ.

Introduction The utilization of Computer-Aided Design and Computer-Aided Manufacturing (CAD/CAM) technology in the production of polyetheretherketone (PEEK) and acetal frameworks enhances the precision and stability of partial denture frameworks. This study evaluates the retentive forces of CAD/CAM-fabricated PEEK, acetal, and cobalt-chromium (Co-Cr) frameworks in removable partial dentures (RPDs). Methods Forty-five frameworks were fabricated (15 each of PEEK, acetal, and Co-Cr) and tested for retentive forces using a universal testing machine at a crosshead speed of 5 mm/min.

View Article and Find Full Text PDF

Upcycling organic and inorganic waste into value-added metal-organic frameworks (MOFs) presents a sustainable strategy for mitigating waste pollution and promoting economic viability. However, rapid synthesis of MOF materials derived from actual industrial waste under mild conditions remains challenging. Herein, Fe-MOF MIL-88B(Fe) was successfully fabricated within 1 h at room temperature using galvanizing pickling waste liquid and terephthalic acid derived from waste poly(ethylene terephthalate).

View Article and Find Full Text PDF

Implantable multifunctional probes have transformed neuroscience research, offering access to multifaceted brain activity that was previously unattainable. Typically, simultaneous access to both optical and electrical signals requires separate probes, while their integration into a single device can result in the emergence of photogenerated electrical artifacts, affecting the quality of high-frequency neural recordings. Among the nontrivial strategies aimed at the realization of an implantable multifunctional interface, the integration of optical and electrical capabilities on a single, minimally invasive, tapered optical fiber probe has been recently demonstrated using fibertrodes.

View Article and Find Full Text PDF

Stepwise Lighting Up Gold(I)-Thiolate Complexes from AIE Nanoaggregates to AIEE Nanoprobes with a ZIF-8 Shell for Glucose Biosensing.

Anal Chem

January 2025

School of Biomedical Engineering, Shenzhen Key Laboratory for Nano-Biosensing Technology, Guangdong Key Laboratory of Biomedical Measurements and Ultrasound Imaging, Marshall Laboratory of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen 518060, China.

Aggregation-induced emission (AIE) or aggregation-induced emission enhancement (AIEE) has endowed gold species with responsive fluorescent properties, favoring their potential applications in sensing, imaging, and therapy. However, it remains an interesting challenge to fabricate fluorophores with both AIE and AIEE effects. Herein, we presented highly luminescent Au(I) thiolate nanocomplex-based biosensors with Zn induced-AIE and zeolite imidazolate framework (ZIF-8) induced-AIEE effects.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!