AI Article Synopsis

  • The study analyzes the morpho-anatomical traits of excessively long anterior calcaneal processes in patients with ankle pain and recurrent sprains, utilizing CT scans of 69 feet.
  • A significant 71% of the examined feet displayed pathological features, particularly a reduced calcaneo-navicular distance and other distinct measurement anomalies compared to normal feet.
  • Four morphotypes of the too-long anterior calcaneal process were classified based on anatomical shape: absence, triangular, rectangular, and coalition, highlighting the process's complex 3D structure.

Article Abstract

Our work aims to identify and measure the morpho-anatomical characteristics of too-long anterior calcaneal process based on computed tomography scans done in patients with a history of pain and who have experienced repeated ankle sprains. The computed tomography scans of 69 feet were reviewed. These scans were used to calculate (1) the calcaneo-navicular distance; (2) the height, length, and width of the too-long anterior calcaneal process; (3) the length of the calcaneum; (4) the angle of the too-long anterior calcaneal process in the sagittal (anterior-superior angle), axial (anterior-medial angle), and frontal plane. Out of 69 feet, forty-nine were pathological (71%) with abnormalities of the too-long anterior calcaneal process, while the rest (29%) had no morphological abnormalities. The calcaneo-navicular distance was found to be <5 mm (mean: 2.8 ± 1.2 mm) in all pathological feet, which also had significantly reduced calcaneo-navicular distance ( P < 0.001) and longer bone portion distal to the calcaneocuboid tangent ( P < 0.001) in comparison to normal feet. In pathological feet, the mean too-long anterior calcaneal process length was 10.7 ± 1.9 mm; the mean anterior-superior angle was 29.6 ° ± 11.6, the mean angle anterior-medial angle was 40.7 ° ± 8.3, the mean angle frontal plane was 74.2 ° ± 14.1. Similar to a cone or a parallelepiped, the too-long anterior calcaneal process has a complex three-dimensional anatomy, with a superior, medial, and anterior direction. Using the measurements obtained, four different too-long anterior calcaneal process morphotypes could be identified: absence of TLACP, triangular shape, rectangular shape, and coalition (level of evidence III).

Download full-text PDF

Source
http://dx.doi.org/10.1097/BPB.0000000000000969DOI Listing

Publication Analysis

Top Keywords

too-long anterior
20
anterior calcaneal
16
calcaneal process
16
computed tomography
12
tomography scans
8
calcaneo-navicular distance
8
too-long
5
anterior
5
process
5
anatomical characterization
4

Similar Publications

The creation of a functional tibial stump after combat injuries is sometimes too difficult. We describe a case of high amputation after a mine-blast injury. In this case, the tibia stump was too short (5 cm) and the fibula stump was too long (12 cm).

View Article and Find Full Text PDF
Article Synopsis
  • AcoA aneurysms are tricky brain problems that can be hard to fix because of their complicated shape and location.
  • Doctors have used different methods, like special surgeries and unique clips, to successfully treat these aneurysms, but sometimes they need to change the clips during the operation.
  • In two cases, doctors had to modify clips to make them fit correctly and safely stop the aneurysms from causing more issues, and both patients ended up doing well afterward.
View Article and Find Full Text PDF

Imaging characteristics of too-long anterior process syndrome in children and adolescents.

Pediatr Radiol

February 2024

Service d'Imagerie de l'Enfant, Hôpital Jeanne de Flandre, CHRU de Lille, Avenue Eugène Avinée, Lille cedex 59037, France.

Background: In the presence of pain over the lateral aspect of the foot or recurrent ankle sprain in children, medical imaging is often employed to investigate potential causes, such as a calcaneonavicular coalition or a too-long anterior process (TLAP) of the calcaneus. Diagnosis and categorization of calcaneonavicular coalitions (synostosis, synchondrosis, or synfibrosis) is generally facilitated through imaging, in contrast to TLAP, which lacks well-defined semiological characteristics, apart from a calcaneonavicular space measurement of less than 5 mm. However, this measurement initially performed on an oblique view radiograph can be subject to a lack of precision due to positional variations of the foot and overlapping bones.

View Article and Find Full Text PDF

Long and short of Ahmed glaucoma valve tube.

Indian J Ophthalmol

November 2023

Department of Glaucoma, Anand Eye Institute, Hyderabad, Telangana, India.

Background: The Ahmed Glaucoma Valve (AGV, New World Medical Inc., Rancho Cucamonga, CA, USA) is a glaucoma drainage device commonly used in the treatment of refractory glaucoma either as a primary surgical procedure or after the failure of conventional filtration procedures. During surgery, After the AGV plate is fixed to the sclera, at least 8 mm posterior to the corneoscleral limbus, the length of tube is trimmed to the desired length, based on decision to insert it in the anterior chamber (AC) or ciliary sulcus.

View Article and Find Full Text PDF

Evaluation of surgical outcomes of calcaneonavicular coalition and too-long anterior process in children: A prospective study.

Orthop Traumatol Surg Res

September 2024

Service de chirurgie pédiatrique, hôpital des Enfants, CHU de Limoges, 8, avenue Dominique-Larrey, 87042 Limoges cedex, France. Electronic address:

Introduction: Calcaneonavicular coalitions (CC) affect approximately 1% of the general population. CC or Too-long anterior process (TLAP) result in "repeated sprains" that can be associated with foot and/or ankle chronic pain. The main objective of this study was to analyze the effectiveness of surgery using the AOFAS score.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!