Continuous cardiac thermometry via simultaneous catheter tracking and undersampled radial golden angle acquisition for radiofrequency ablation monitoring.

Sci Rep

IHU Liryc, Electrophysiology and Heart Modeling Institute, Hopital Xavier Arnozan, Foundation Bordeaux Université, Avenue du Haut Lévêque, 33604, Pessac Cedex, France.

Published: March 2022

The complexity of the MRI protocol is one of the factors limiting the clinical adoption of MR temperature mapping for real-time monitoring of cardiac ablation procedures and a push-button solution would ease its use. Continuous gradient echo golden angle radial acquisition combined with intra-scan motion correction and undersampled temperature determination could be a robust and more user-friendly alternative than the ultrafast GRE-EPI sequence which suffers from sensitivity to magnetic field susceptibility artifacts and requires ECG-gating. The goal of this proof-of-concept work is to establish the temperature uncertainty as well as the spatial and temporal resolutions achievable in an Agar-gel phantom and in vivo using this method. GRE radial golden angle acquisitions were used to monitor RF ablations in a phantom and in vivo in two sheep hearts with different slice orientations. In each case, 2D rigid motion correction based on catheter micro-coil signal, tracking its motion, was performed and its impact on the temperature imaging was assessed. The temperature uncertainty was determined for three spatial resolutions (1 × 1 × 3 mm, 2 × 2 × 3 mm, and 3 × 3 × 3 mm) and three temporal resolutions (0.48, 0.72, and 0.97 s) with undersampling acceleration factors ranging from 2 to 17. The combination of radial golden angle GRE acquisition, simultaneous catheter tracking, intra-scan 2D motion correction, and undersampled thermometry enabled temperature monitoring in the myocardium in vivo during RF ablations with high temporal (< 1 s) and high spatial resolution. The temperature uncertainty ranged from 0.2 ± 0.1 to 1.8 ± 0.2 °C for the various temporal and spatial resolutions and, on average, remained superior to the uncertainty of an EPI acquisition while still allowing clinical monitoring of the RF ablation process. The proposed method is a robust and promising alternative to EPI acquisition to monitor in vivo RF cardiac ablations. Further studies remain required to improve the temperature uncertainty and establish its clinical applicability.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8901729PMC
http://dx.doi.org/10.1038/s41598-022-06927-9DOI Listing

Publication Analysis

Top Keywords

golden angle
16
temperature uncertainty
16
radial golden
12
motion correction
12
simultaneous catheter
8
catheter tracking
8
temperature
8
intra-scan motion
8
correction undersampled
8
temporal resolutions
8

Similar Publications

Combination of deep learning reconstruction and quantification for dynamic contrast-enhanced (DCE) MRI.

Magn Reson Imaging

December 2024

Weill Cornell Graduate School of Medical Sciences, New York, NY, United States; Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, United States; Department of Radiology, Memorial Sloan Kettering Cancer Center, NY, New York, USA. Electronic address:

Dynamic contrast-enhanced (DCE) MRI is an important imaging tool for evaluating tumor vascularity that can lead to improved characterization of tumor extent and heterogeneity, and for early assessment of treatment response. However, clinical adoption of quantitative DCE-MRI remains limited due to challenges in acquisition and quantification performance, and lack of automated tools. This study presents an end-to-end deep learning pipeline that exploits a novel deep reconstruction network called DCE-Movienet with a previously developed deep quantification network called DCE-Qnet for fast and quantitative DCE-MRI.

View Article and Find Full Text PDF

Resonance theory of vibrational polariton chemistry at the normal incidence.

Nanophotonics

June 2024

Department of Chemistry, University of Rochester, 120 Trustee Road, Rochester, NY 14627, USA.

We present a theory that explains the resonance effect of the vibrational strong coupling (VSC) modified reaction rate constant at the normal incidence of a Fabry-Pérot (FP) cavity. This analytic theory is based on a mechanistic hypothesis that cavity modes promote the transition from the ground state to the vibrational excited state of the reactant, which is the rate-limiting step of the reaction. This mechanism for a single molecule coupled to a single-mode cavity has been confirmed by numerically exact simulations in our recent work in [J.

View Article and Find Full Text PDF

Unsupervised reconstruction of accelerated cardiac cine MRI using neural fields.

Comput Biol Med

December 2024

Millennium Nucleus for Applied Control and Inverse Problems, Santiago, Chile; Millennium Institute for Intelligent Healthcare Engineering, Santiago, Chile; Department of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom; School of Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile.

Background: Cardiac cine MRI is the gold standard for cardiac functional assessment, but the inherently slow acquisition process creates the necessity of reconstruction approaches for accelerated undersampled acquisitions. Several regularization approaches that exploit spatial-temporal redundancy have been proposed to reconstruct undersampled cardiac cine MRI. More recently, methods based on supervised deep learning have been also proposed to further accelerate acquisition and reconstruction.

View Article and Find Full Text PDF

Design of Two-Dimensional Hybrid Perovskites with Giant Spin Splitting and Persistent Spin Textures.

J Am Chem Soc

December 2024

Thomas Lord Department of Mechanical Engineering and Materials Science, Duke University, Durham, North Carolina 27708, United States.

Semiconductors with large energetic separation Δ of energy sub-bands with distinct spin expectation values (spin textures) represent a key target to enable control over spin transport and spin-optoelectronic properties. While the paradigmatic case of symmetry-dictated Rashba spin splitting and associated spin textures remains the most explored pathway toward designing future spin-transport-based quantum information technologies, controlling spin physics beyond the Rashba paradigm by accessing strategically targeted crystalline symmetries holds significant promise. In this paper, we show how breaking the traditional paradigm of octahedron-rotation based structure distortions in 2D organic-inorganic perovskites (2D-OIPs) can facilitate exceptionally large spin splittings (Δ > 400 meV) and spin textures with extremely short spin helix lengths ( ∼ 5 nm).

View Article and Find Full Text PDF

Background And Objectives: Vestibular schwannomas demonstrate different responses after stereotactic radiosurgery (SRS), commonly including a transient loss of internal enhancement on postcontrast T1-weighted MRI thought to be due to an early reduction in tumor vascularity. We used dynamic contrast-enhanced based golden-angle radial sparse parallel (GRASP) MRI to characterize the vascular permeability changes underlying this phenomenon, with correlations to long-term tumor regression.

Methods: Consecutive patients with vestibular schwannoma who underwent SRS between 2017 and 2019, had a transient loss of enhancement after SRS, and had long-term longitudinal GRASP studies (6, 18, and 30 months) were included in this retrospective cohort analysis (n = 19).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!