For people with physical disabilities, manual wheelchairs are essential enablers of mobility, participation in society, and a healthy lifestyle. Their most general design offers great flexibility and direct feedback, but has been described to be inefficient and demands good coordination of the upper extremities while critically influencing users' actions. Multiple research groups have used Inertial Measurement Units (IMUs) to quantify physical activities in wheelchairs arguing that knowledge over behavioural patterns in manual wheelchair usage can guide technological development and improved designs. The present study investigates turning behaviour among fulltime wheelchair users, laying the foundation of the development of novel steering systems that allow directing kinetic energy by means other than braking. Three wearable sensors were installed on the wheelchairs of 14 individuals for tracking movement over an entire week. During detected "moving windows", phases where the velocities of the two rear wheels differed by more than 0.05 m/s were considered as turns. Kinematic characteristics for both turns-on-the-spot as well as for moving turns were then derived from the previously reconstructed wheeled path. For the grand total of 334 km of recorded wheelchair movement, a turn was detected every 3.6 m, which equates to about 900 turns per day on average and shows that changing and adjusting direction is fundamental in wheelchair practice. For moving turns, a median turning radius of 1.09 m and a median turning angle of 39° were found. With a median of 89°, typical turning angles were considerably larger for turns-on-the-spot, which accounted for roughly a quarter of the recognised turns and often started from a standstill. These results suggest that a frequent pattern in daily wheelchair usage is to initiate movement with an orienting turn-on-the-spot, and cover distances with short, straightforward sections while adjusting direction in small and tight moving turns. As large bends often require simultaneous pushing and breaking, this is, perhaps, the result of users intuitively optimising energy efficiency, but more research is needed to understand how the design of the assistive devices implicitly directs users' movement.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8892830PMC
http://dx.doi.org/10.3389/fbioe.2022.831528DOI Listing

Publication Analysis

Top Keywords

moving turns
12
manual wheelchair
8
steering systems
8
wheelchair usage
8
adjusting direction
8
median turning
8
wheelchair
6
turns
6
turning
5
turning circles
4

Similar Publications

Microtextured microneedles are tiny needle-like structures with micron-scale microtextures, and the drugs stored in the microtextures can be released after entering the skin to achieve the effect of precise drug delivery. In this study, the skin substitution model of Ogden's hyperelastic model and the microneedle array and microtexture models with different geometrical parameters were selected to simulate and analyse the flow of the microtexture microneedle arrays penetrating the skin by the finite-element method, and the length of the microneedles was determined to be 200 μm, the width 160 μm, and the value of the gaps was determined to be 420 μm. A four-pronged cone was chosen as the shape of microneedles, and a rectangle was chosen as the shape of the drug-carrying microneedle.

View Article and Find Full Text PDF

Many flights, with their precise positioning capabilities, have provided rich inspiration for designing insect-styled micro air vehicles. However, researchers have not widely studied their flight ability. In particular, research on the maneuverability of using integrated kinematics and aerodynamics is scarce.

View Article and Find Full Text PDF

At the right time: Moving precision therapy to newly diagnosed cancer.

Med

December 2024

MCW Cancer Center, Medical College of Wisconsin, Milwaukee, WI, USA; WIN Consortium, Paris, France. Electronic address:

Precision oncology aims to match the right drug(s) to the right patient. Equally important is ensuring that precision therapies are offered at the right time. Transformative, rather than incremental, outcome improvement may require treatment at diagnosis rather than in the advanced/metastatic setting after genomic evolution.

View Article and Find Full Text PDF

Rapid urbanization, economic expansion, and population growth have increased waste generation in many nations worldwide. Research on municipal waste management (MWM) is moving towards new frontiers in efficiency and applicability due to the growing amount of data being collected in these systems and the convergence of various technological applications; artificial intelligence (AI) techniques present novel and creative alternatives for MWM. Even though much research has been conducted in this field, relatively few review studies assess how advancements in AI techniques can contribute to the sustainable advancement of MWM systems.

View Article and Find Full Text PDF

The Influence of Occupant Characteristics, Seat Positioning, and Pre-Crash Maneuvers on Front Passenger Safety Performance.

J Biomech Eng

December 2024

Department of Biomedical Engineering and Mechanics, Virginia Tech, Blacksburg, VA.

Crash avoidance vehicle maneuvers are known to influence occupant posture and kinematics which consequently may influence injury risks in the event of a crash. In this work, a generic buck vehicle finite element (FE) model was developed which included the vehicle interior and the front passenger airbag (PAB). Seat position and occupant characteristics including anthropometry, sex, and age were varied in a design of experiments.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!