Backgroud: Attune (DePuy Synthes) prosthesis was designed to overcome patellofemoral complications associated with PFC Sigma (DePuy Synthes) prosthesis. The aim of our study was to compare the incidence of anterior knee pain (AKP), patellofemoral crepitus (PCr), and functional outcome between them.

Methods: This prospective matched-pair study was conducted between January 2014 and June 2015, during which 75 consecutive Attune total knee arthroplasties (TKAs) were matched with 75 PFC Sigma TKAs based on age, sex, body mass index, pathology, and deformity. A single surgeon performed all the operations with aid of computer navigation, using a posterior-stabilized prosthesis with patellar resurfacing. Outcome was assessed by new Knee Society Score (NKSS) and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score. AKP and PCr were assessed by a patient-administered questionnaire till 2 years of follow-up. Three pairs were lost to follow-up and finally 72 pairs were analyzed.

Results: One patient in each group reported AKP and 1 patient from each group had PCr at 2 years postoperatively. None of these patients required additional surgery. The incidence of lateral retinacular release was higher with PFC Sigma (5/72) than Attune (2/72); however, this was statistically not significant ( = 0.4). The Attune group had a significantly greater range of motion (ROM) at 3 months postoperatively ( = 0.049). At final follow-up, ROM was comparable between two prosthesis designs. NKSS and WOMAC scores were also comparable between the groups.

Conclusions: We observed that both Attune and PFC Sigma had a low and comparable incidence of AKP and PCr up to 2 years of follow-up. The Attune group achieved a significantly greater ROM at 3 months postoperatively. At 2 years of follow-up, both prostheses had excellent and comparable clinical and functional results.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8858905PMC
http://dx.doi.org/10.4055/cios20130DOI Listing

Publication Analysis

Top Keywords

pfc sigma
20
years follow-up
12
attune pfc
8
prospective matched-pair
8
depuy synthes
8
synthes prosthesis
8
akp pcr
8
patient group
8
pcr years
8
attune group
8

Similar Publications

Background: Application time and viscosity are factors that can significantly affect the properties of bone cement and implant fixation. The aim of this study was to investigate the influence of different application times of 2 different cements on mechanical parameters, cement interdigitation, and cement distribution.

Methods: P.

View Article and Find Full Text PDF

Individuals suffering from obsessive compulsive disorder (OCD) and schizophrenia (SCZ) frequently exhibit symptoms of cognitive disassociations, which are linked to poor functional integration among brain regions. The loss of functional integration can be assessed using graph metrics computed from functional connectivity matrices (FCMs) derived from neuroimaging data. A healthy brain at rest is known to exhibit small-world features with high clustering coefficients and shorter path lengths in contrast to random networks.

View Article and Find Full Text PDF

Introduction: Major depressive disorder (MDD) is a common and disabling mental health condition; the currently available treatments for MDD are insufficient to meet clinical needs due to their limited efficacy and slow onset of action. Hypidone hydrochloride (YL-0919) is a sigma-1 receptor agonist and a novel fast-acting antidepressant that is currently under clinical development.

Methods: To further understand the fast-acting antidepressant activity of YL-0919, this study focused on the role of 5-HTergic neurons in the dorsal raphe nucleus (DRN) in mice.

View Article and Find Full Text PDF

Background: The Attune TKR was introduced in 2011 as a successor to its predicate design The PFC Sigma. However, following reports of early failures, there are ongoing concerns related to increased loosening rates. Given the concerns, this study aimed to compare revision rates of the Attune implant to an established predicate, and other implant designs used in a high-volume arthroplasty center.

View Article and Find Full Text PDF

Aims: The mean age of patients undergoing total knee arthroplasty (TKA) has reduced with time. Younger patients have increased expectations following TKA. Aseptic loosening of the tibial component is the most common cause of failure of TKA in the UK.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!