Background: Quantitative MR-neurography (MRN) is increasingly applied, however, the impact of the MR-scanner on the derived parameters is unknown. Here, we used different 3.0T MR scanners and applied comparable MR-sequences in order to quantify the inter-scanner reproducibility of various MRN parameters of the sciatic nerve.
Methods: Ten healthy volunteers were prospectively examined at three different 3.0T MR scanners and underwent MRN of their sciatic nerve using comparable imaging protocols including diffusion tensor imaging (DTI) and T2 relaxometry. Subsequently, inter-scanner agreement was assessed for seven different parameters by calculating the intraclass correlation coefficients (ICCs) and the standard error of measurement (SEM).
Results: Assessment of inter-scanner reliability revealed good to excellent agreement for T2 (ICC: 0.846) and the quantitative DTI parameters, such as fractional anisotropy (FA) (ICC: 0.876), whereas moderate agreement was observed for proton spin density (PD) (ICC: 0.51). Analysis of variance identified significant inter-scanner differences for several parameters, such as FA ( < 0.001; = 0.02), T2 ( < 0.01) and PD ( = 0.02; < 0.01; = 0.02). Calculated SEM values were mostly within the range of one standard deviation of the absolute mean values, for example 0.033 for FA, 4.12 ms for T2 and 27.8 for PD.
Conclusion: This study quantifies the measurement imprecision for peripheral nerve DTI and T2 relaxometry, which is associated with the use of different MR scanners. The here presented values may serve as an orientation of the possible scanner-associated fluctuations of MRN biomarkers, which can occur under similar conditions.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8888927 | PMC |
http://dx.doi.org/10.3389/fnins.2022.817316 | DOI Listing |
Sci Rep
January 2025
Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China.
This study aimed to investigate the diagnostic and evaluative significance of combining median nerve (MN) morphological measurements with diffusion tensor imaging (DTI) and T2 mapping metrics for carpal tunnel syndrome (CTS). Morphological and multiparametric magnetic resonance neurography (MRN), along with clinical evaluation, were conducted on 33 CTS patients and 32 healthy controls. The MRN metrics included fractional anisotropy (FA), apparent diffusion coefficient (ADC), axial diffusivity (AD), radial diffusivity (RD), T2 value, cross-sectional area (CSA) and MN flattening ratio (MNFR) at both the pisiform bone and hamate bone levels.
View Article and Find Full Text PDFLin Chuang Er Bi Yan Hou Tou Jing Wai Ke Za Zhi
January 2025
To exploring the value of MR neuroimaging for quantitative assessment of the facial nerve and peripheral lymph nodes in patients with acute peripheral facial paralysis. Based on a prospective experimental design, 32 patients with idiopathic peripheral facial palsy were enrolled in the experiment. Based on MR neuroimaging technology, MR high-resolution thin-layer images of bilateral facial nerves were acquired.
View Article and Find Full Text PDFJ Magn Reson Imaging
September 2024
Institute of Diagnostic and Interventional Radiology, University Hospital Zurich (USZ), Zurich, Switzerland.
Background: Intravenous Ferumoxtran-10 belongs to ultra-small superparamagnetic iron oxide particles and can be used for magnetic resonance neurography (MRN) as an alternative to other imaging methods which use contrast agents.
Purpose: To examine the impact of intravenous Ferumoxtran-10 on vascular suppression and compare image quality to gadolinium (Gd)-enhanced image acquisition in MRN of lumbosacral plexus (LS).
Study Type: Prospective.
Eur Radiol Exp
August 2024
Institute of Neuroradiology, University Hospital of Heidelberg, Heidelberg, Germany.
Background: Magnetic resonance neurography (MRN) is increasingly used as a diagnostic tool for peripheral neuropathies. Quantitative measures enhance MRN interpretation but require nerve segmentation which is time-consuming and error-prone and has not become clinical routine. In this study, we applied neural networks for the automated segmentation of peripheral nerves.
View Article and Find Full Text PDFBMC Oral Health
June 2024
Department of Oral and Maxillofacial Surgery, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
Background: Iatrogenic mandibular nerve damage resulting from oral surgeries and dental procedures is painful and a formidable challenge for patients and oral surgeons alike, mainly because the absence of objective and quantitative methods for diagnosing nerve damage renders treatment and compensation ambiguous while often leading to medico-legal disputes. The aim of this study was to examine discriminating factors of traumatic mandibular nerve within a specific magnetic resonance imaging (MRI) protocol and to suggest tangible diagnostic criteria for peripheral trigeminal nerve injury.
Methods: Twenty-six patients with ipsilateral mandibular nerve trauma underwent T2 Flex water, 3D short tau inversion recovery (STIR), and diffusion-weighted imaging (DWI) acquired by periodically rotating overlapping parallel lines with enhanced reconstruction (PROPELLER) pulse sequences; 26 injured nerves were thus compared with contra-lateral healthy nerves at anatomically corresponding sites.