Flexible pressure sensors may be used in electronic skin (e-skin), artificial intelligence devices, and disease diagnosis, which require a large response range and high sensitivity. An appropriate design of the structure of the active layer can help effectively solve this problem. Herein, we aim at developing a wearable pressure sensor using the MXene/ZIF-67/polyacrylonitrile (PAN) nanofiber film, fabricated by electrospinning technology. Owing to the rough structure and three-dimensional network architecture, the MXene/ZIF-67/PAN film-based device displays a broad working range (0-100 kPa), good sensitivity (62.8 kPa), robust mechanical stability (over 10,000 cycles), and fast response/recovery time (10/8 ms). Moreover, the fabricated pressure sensors can be used to detect and differentiate between different body motion information, including elbow bending, finger movements, and wrist pulses. Overall, this design of a rough three-dimensional conductive network structure shows potential in the field of wearable electronics and medical devices.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acsami.1c24655 | DOI Listing |
J Foot Ankle Res
March 2025
The University of South Australia, Allied Health & Human Performance Unit, Adelaide, SA, Australia.
Background: This study investigated the effect of various offloading devices commonly used for the management of diabetic foot ulcerations on peak plantar pressure and pressure-time integral of the contralateral limb.
Methods: A quantitative, randomised and within-subject repeated measures study was conducted in an outpatient gait laboratory. Outpatients with unilateral diabetic foot ulcers and adequate perfusion to the lower limb without an intrinsic limb-length discrepancy who were able to walk were recruited for the study.
Adv Mater
January 2025
Division of Intelligent and Biomechanical Systems, State Key Laboratory of Tribology in Advanced Equipment, Department of Mechanical Engineering, Tsinghua University, Haidian, Beijing, 100084, China.
Quantitative assessment for post-stroke spasticity remains a significant challenge due to the encountered variable resistance during passive stretching, which can lead to the widely used modified Ashworth scale (MAS) for spasticity assessment depending heavily on rehabilitation physicians. To address these challenges, a high-force-output triboelectric soft pneumatic actuator (TENG-SPA) inspired by a lobster tail is developed. The bioinspired TENG-SPA can generate approximately 20 N at 0.
View Article and Find Full Text PDFSensors (Basel)
January 2025
School of Mechanical, Aerospace & Civil Engineering, University of Sheffield, Sheffield S1 3JD, UK.
Stress wave dispersion can result in the loss or distortion of critical high-frequency data during high-strain-rate material tests or blast loading experiments. The purpose of this work is to demonstrate the benefits of correcting stress wave dispersion in split-Hopkinson pressure bar experiments under various testing situations. To do this, an innovative computational algorithm, SHPB_Processing.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Facultad de Ciencias de la Actividad Física y del Deporte-INEF, Universidad Politécnica de Madrid, 28040 Madrid, Spain.
The aim of this study was to understand and describe the physiological and biomechanical demands of various tasks used in basketball training and, subsequently, to provide a practical application of these tasks in a typical training week. Twelve basketball players had their external load variables monitored across 179 training sessions (2896 samples) using local positioning system technology. These variables included total distance covered, distance covered at various intensity levels, accelerations, decelerations, PlayerLoad™, and explosive efforts.
View Article and Find Full Text PDFSensors (Basel)
January 2025
State Key Laboratory of Petroleum Resources and Prospecting, China University of Petroleum, Beijing 102249, China.
Transducers used in acoustic logging while drilling (ALWD) must be mounted on a drill collar, and their radiation performance is dependent on the employed mounting method. Herein, the complex transmitting voltage response of a while-drilling (WD) monopole acoustic source was calculated through finite-element harmonic-response analysis. Subsequently, the acoustic pressure waveform radiated by the source driven by a half-sine excitation voltage signal was calculated using the complex transmitting voltage response.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!