Objectives: The objective of this study was to compare waveforms obtained with a new device for the non-invasive monitoring of intracranial pressure (ICP) in dogs with and without neurological disease.
Materials And Methods: This prospective study was conducted on both neurologically normal dogs and dogs with neurological diseases. First, non-invasive ICP waveforms were recorded in normal dogs using the Braincare® BcMM 2000 monitor while the dogs were under general anaesthesia induced for procedures unrelated to this study. The dogs were positioned in lateral recumbency, and the sensor was placed over the skin of the parietal region. Secondly, non-invasive ICP waveforms were monitored in dogs with brain and spinal disease until waveforms with characteristic peaks were acquired. All the recorded signals were amplified, filtered and digitalized, by the device, and then transferred to a computer for analysis.
Results: Normal pulse waveforms indicating normal brain complacency were observed in eight neurologically normal dogs. In six dogs with brain disease, abnormal pulse waveforms were observed suggesting increased ICP and decreased brain complacency. Four dogs with spinal disease undergoing myelography, had normal waveforms before contrast medium injection and abnormal pulse waveforms during contrast medium injection, indicating a potential increase in ICP.
Clinical Significance: Based on these preliminary observations, this method was capable of detecting abnormal pulse waveforms that suggested increased ICP.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/jsap.13460 | DOI Listing |
Ultrasonics
January 2025
Medical Ultrasound Department for the Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu 215163, China. Electronic address:
Shear Wave Elastography (SWE) is an imaging technique that detects shear waves generated by tissue excited by Acoustic Radiation Force (ARF), and characterizes the mechanical properties of soft tissue by analyzing the propagation velocity of shear wave. ARF induces a change in energy density through the nonlinear propagation of ultrasound waves, which drives the tissue to generate shear waves. However, the amplitude of shear waves generated by ARF is weak, and the shear waves are strongly attenuated in vivo.
View Article and Find Full Text PDFJ Clin Hypertens (Greenwich)
January 2025
Department of Geriatrics, Medical Center on Aging of Shanghai Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China.
The aim of this study was to explore whether 24-h ambulatory central (aortic) blood pressure (BP) has an advantage over office central aortic BP in screening for hypertension-mediated target organ damage (HMOD). A total of 714 inpatients with primary hypertension and the presence of several cardiovascular risk factors or complications involving clinical HMOD were enrolled. Twenty-four hour central aortic BP was measured by means of a noninvasive automated oscillometric device (Mobil-O-Graph).
View Article and Find Full Text PDFJ Clin Hypertens (Greenwich)
January 2025
Department of Cardiovascular Medicine, Shanghai Key Laboratory of Hypertension, Shanghai Institute of Hypertension, State Key Laboratory of Medical Genomics, National Research Centre for Translational Medicine, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China.
Prognostic significance of the timing in the cardiac cycle of the first (TP1) and second (TP2) systolic peak of the central aortic pulse wave is ill-defined. Incidence rates and standardized multivariable-adjusted hazard ratios (HRs) of adverse health outcomes associated with TP1 and TP2, estimated by the SphygmoCor software, were assessed in the International Database of Central Arterial Properties for Risk Stratification (IDCARS) (n = 5529). Model refinement was assessed by the integrated discrimination (ID) and net reclassification (NR) improvement.
View Article and Find Full Text PDFPhysiol Meas
January 2025
Faculty of Sciences, University of Coimbra, Palacio de las Escuelas 3004-531, Coimbra, 3004-504, PORTUGAL.
Objective: The detection of arterial pulsating signals at the skin periphery with Photoplethysmography (PPG) are easily distorted by motion artifacts. This work explores the alternatives to the aid of PPG reconstruction with movement sensors (accelerometer and/or gyroscope) which to date have demonstrated the best pulsating signal reconstruction.
Approach: A generative adversarial network with fully connected layers (FC-GAN) is proposed for the reconstruction of distorted PPG signals.
Sci Rep
January 2025
Department of Electrical Engineering, Faculty of Engineering, Al-Azhar University, Cairo, Egypt.
This article presents an innovative asymmetric multilevel inverter (MLI) topology that outperforms conventional counterparts. The introduced topology presents a breakthrough in implementing power electronics control by maximizing specific levels while minimizing switching components. A cutting-edge control scheme for optimal operation of the cascaded half-bridge MLI is presented.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!