Patent ductus arteriosus closure by catheter-based interventions has become the preferred therapeutic choice. However, hemodynamic perturbances associated to this procedure have not yet been investigated. This study sought to examine the on-site hemodynamic impact caused by the procedure in preterm neonates. In this study, hemodynamic monitoring was obtained in a non-invasive way using electrical cardiometry in five preterm infants who underwent percutaneous patent ductus arteriosus closing at ASST Grande Ospedale Metropolitano Niguarda of Milan. All five infants underwent successful transcatheter closures. All patients experienced immediate hemodynamic changes upon ductal closing. Significative modifications occurred mainly in heart contractility, cardiac output, and stroke volume. In three cases, there was also a significative increase of systemic vascular resistance which persisted for 4 h after closing. While in two cases they spontaneously reduced with an amelioration of cardiac output and contractility, in the other case they were persistently high, associated with an hypertensive crisis and a progressive reduction of cardiac functions. For these reasons, milrinone was started and hemodynamic parameters returned normal in about 3 h, so therapy was discontinued. Conclusions: Our single-center, prospective, consecutive, case series demonstrated hemodynamic aberrations due to sudden closure of a patent ductus arteriosus. Moreover, post procedural hemodynamic monitoring is important to precociously detect possible cardiac impairment and start an adequate therapy. What is Known: • It has previously suggested a temporarily impairment in cardiac output following patent ductus arteriosus closing. • Little is known about the other hemodynamic parameters during the procedure and how they change in the next hours according to the new hemodynamic status. What is New: • The persistence of increased systemic vascular resistance after percutaneous closure of ductus arteriosus could suggest the occurrence of hemodynamic complications. • Electrical cardiometry was useful to early detect postoperative hemodynamic changes.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00431-022-04426-7 | DOI Listing |
Magn Reson Med
January 2025
Department of Radiology & Nuclear Medicine, Amsterdam University Medical Center, University of Amsterdam, Amsterdam, The Netherlands.
Purpose: To correct maternal breathing and fetal bulk motion during fetal 4D flow MRI.
Methods: A Doppler-ultrasound fetal cardiac-gated free-running 4D flow acquisition was corrected post hoc for maternal respiratory and fetal bulk motion in separate automated steps, with optional manual intervention to assess and limit fetal motion artifacts. Compressed-sensing reconstruction with a data outlier rejection algorithm was adapted from previous work.
Am J Perinatol
January 2025
Pediatrics, University of California San Francisco, San Francisco, United States.
Objective: Extremely premature infants are treated with acetaminophen (APAP) for pain and patent ductus arteriosus. High doses of APAP in adults are toxic, and a recent study found an association between APAP metabolite levels in mothers' breast milk and both bronchopulmonary dysplasia (BPD) and retinopathy of prematurity (ROP) in their premature infants. In this study, we determined levels of APAP metabolites in urine of infants at high risk for BPD and ROP.
View Article and Find Full Text PDFCureus
December 2024
Pediatrics, Alessandrescu-Rusescu National Institute of Mother and Child Health, Bucharest, ROU.
Introduction: Congenital heart disease (CHD) is diagnosed with high prevalence. Pulse oximetry and clinical examination are screening tools to aid in obtaining a CHD diagnosis.
Materials And Methods: We conducted a retrospective longitudinal study over three years, screening 1188 newborns admitted to the neonatal intensive care unit (NICU) during the first 72 hours of life.
Cardiol Young
January 2025
Department of Pediatrics, Seoul National University Children's Hospital, Seoul National University College of Medicine, Seoul, Korea.
Hybrid procedure of hypoplastic left heart syndrome, comprising ductus arteriosus stenting and bilateral pulmonary artery banding, is a good surgical option for initial palliative procedure for high-risk patients for Norwood procedure. However, ductal stenting may cause retrograde aortic blood flow obstruction. Furthermore, complete removal of stent while performing the Norwood procedure make the operation more difficult.
View Article and Find Full Text PDFClin Case Rep
January 2025
Department of Radiology and Radiotherapy, School of Medicine, College of Health Sciences Makerere University Kampala Uganda.
Double outlet right ventricle (DORV) is a rare congenital heart defect where both the aorta and pulmonary artery originate from the right ventricle, often accompanied by additional cardiac anomalies to mitigate circulatory imbalance, though such compensations usually fail. We report a 15-month-old infant with recurrent respiratory infections and poor weight gain, referred for computed tomography angiography. Physical examination showed a small, non-syndromic infant with pallor, tachypnea, irritability, and finger clubbing.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!