A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Reliable pace termination of postoperative atrial fibrillation in the canine sterile pericarditis model: Implications for atypical atrial flutter. | LitMetric

Background: We have identified a reentrant circuit in the pulmonary vein region, which drives the atria, producing fibrillatory conduction, as one mechanism of postoperative atrial fibrillation (POAF) in the canine sterile pericarditis model.

Objective: In this model, we tested the hypothesis that overdrive pacing from a site at or near such a reentrant circuit would interrupt it and thereby terminate POAF.

Methods: We studied 11 sterile pericarditis dogs on postoperative days 1-4. Atrial electrograms (AEGs) were recorded during POAF, overdrive pacing, and pace termination from 3 sites simultaneously: Bachmann's bundle, posterior left atrium, and right atrial appendage. When recorded AEGs demonstrated regular activation, pace termination was attempted at that site by delivering a drive train starting with 4 consecutive beats at a cycle length (CL) of 2-5 ms shorter than that of the intrinsic CL.

Results: Sixteen episodes of sustained POAF (>5 minutes) diagnosed by electrocardiogram were induced. During all episodes of POAF, AEGs recorded from the left atrium exhibited regular activation, ie, constant AEG morphology and CL. When capture of the reentrant circuit by overdrive pacing occurred (mean 13 ± 5, range 5-23 beats), all 16 POAF episodes were successfully terminated. In all termination episodes, at the end of pacing but prior to the return of sinus rhythm, there was disorganized atrial activation in the previously organized sites (mean 2 seconds, range 0.1-8 seconds). However, these beats did not sustain POAF in the absence of a reentrant circuit ("driver").

Conclusion: Overdrive pacing from a site demonstrating regular activation during sustained POAF terminated the POAF by interrupting the reentrant circuit.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8859807PMC
http://dx.doi.org/10.1016/j.hroo.2022.01.003DOI Listing

Publication Analysis

Top Keywords

reentrant circuit
20
overdrive pacing
16
pace termination
12
sterile pericarditis
12
regular activation
12
postoperative atrial
8
atrial fibrillation
8
canine sterile
8
poaf
8
pacing site
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!