Background: Instability is a common complication after revision total hip arthroplasty. Tripolar constrained (TC) and dual mobility (DM) liners cemented into tantalum acetabular revision (TM) shells are established alternatives that reduce instability risk. This study compares outcomes of TC and DM liners cemented into TM shells in complex revision hip replacements.

Methods: Fifty cases using a TM shell and a TC or DM cemented liner with at least 12 months of follow-up were identified. There were 25 TC and 25 DM liners. Clinical, radiographic, and patient-reported outcomes were collected. Reasons for re-revision and failures were analyzed.

Results: The average age was 73 years in the TC group and 75 years in the DM group. The median follow-up duration was 50 months (23 - 96) and 13 months (12 - 21) for the TC and DM groups, respectively. The mean Harris Hip Score improved from 37 to 61 for the TC group and from 51 to 73 in the DM group at the last review. Two TC cases required revision for wear and liner failure. One DM insert was changed at reoperation for periprosthetic femur fracture. There were no failures of cement fixation in either group and no revisions for cup loosening.

Conclusions: In complex revision hip replacement with a history of instability or judged to have a high risk of instability postoperatively, TC and DM liners cemented into tantalum revision shells are both successful, giving acceptable results. The improved arc of movement with DM liners, minimizing impingement, makes them preferable except when there is a global abductor deficiency or severe joint laxity.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8881686PMC
http://dx.doi.org/10.1016/j.artd.2021.12.011DOI Listing

Publication Analysis

Top Keywords

cemented tantalum
12
revision shells
12
complex revision
12
liners cemented
12
tripolar constrained
8
constrained dual
8
dual mobility
8
mobility liners
8
tantalum acetabular
8
revision
8

Similar Publications

Purpose: Acetabular defect reconstruction can be a complex and challenging surgical procedure, with stable long-term fixation of the implants remaining the ultimate goal. The purpose of this study was (1) to evaluate the radiological and clinical outcome of complex acetabular reconstruction surgery with the use of modular tantalum TM augments in combination with cemented revision cups; (2) to investigate blood tantalum concentrations in these patients; and (3) to report complications and mechanisms of failure related to this procedure at mid-term follow-up (mean 4.5 years).

View Article and Find Full Text PDF

The incidence of spondylodiscitis has witnessed a significant increase in recent decades. Surgical intervention becomes necessary in case of bone destruction to remove infected tissue and restore spinal stability, often involving the implantation of a cage. Despite appropriate treatment, relapses occur in up to 20 percent of cases, resulting in substantial economic and social burdens.

View Article and Find Full Text PDF

Radiopaque and Biocompatible PMMA Bone Cement Triggered by Nano Tantalum Carbide and Its Osteogenic Performance.

ACS Biomater Sci Eng

September 2024

College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou, Jiangsu 215123, China.

Poly(methyl methacrylate) (PMMA) bone cements have been widely used in orthopedics; thanks to their excellent mechanical properties, biocompatibility, and chemical stability. Barium sulfate and zirconia are usually added into PMMA bone cement to enhance the X-ray radiopacity, while the mechanical strength, radiopacity, and biocompatibility are not well improved. In this study, an insoluble and corrosion-resistant ceramic, tantalum carbide (TaC), was added into the PMMA bone cement as radiopacifies, significantly improving the mechanical, radiopaque, biocompatibility, and osteogenic performance of bone cement.

View Article and Find Full Text PDF

Extensor mechanism (EM) disruption is a rare but severe complication of total knee arthroplasty (TKA) that can greatly impair function. Treatment options for chronic patella tendon ruptures include primary repair, autograft augmentation, and reconstruction with allograft or synthetic material. Despite various techniques, failures can occur, and options for reconstruction after a failed allograft or mesh are limited, especially if the tibial component is well-fixed and cannot be easily removed, and if there is proximal tibial deficiency from a previous failed EM allograft.

View Article and Find Full Text PDF

Aims: Micromotion of the polyethylene (PE) inlay may contribute to backside PE wear in addition to articulate wear of total knee arthroplasty (TKA). Using radiostereometric analysis (RSA) with tantalum beads in the PE inlay, we evaluated PE micromotion and its relationship to PE wear.

Methods: A total of 23 patients with a mean age of 83 years (77 to 91), were available from a RSA study on cemented TKA with Maxim tibial components (Zimmer Biomet).

View Article and Find Full Text PDF