Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8910812PMC
http://dx.doi.org/10.3174/ajnr.A7435DOI Listing

Publication Analysis

Top Keywords

z-shift quality
4
quality management
4
management system
4
system level
4
level testing
4
testing standardization
4
standardization neuroimaging
4
neuroimaging pipelines
4
z-shift
1
management
1

Similar Publications

Normalization Based on Shift and Ion Intensity in SALDI-TOFMS Imaging of Samples with Non-Horizontal Surface.

Mass Spectrom (Tokyo)

December 2024

Department of Pharmaceutical Engineering, Faculty of Engineering, Toyama Prefectural University, 5180 Kurokawa, Imizu-City, Toyama 939-0398, Japan.

Matrix-assisted laser desorption/ionization (MALDI), surface-assisted laser desorption/ionization (SALDI), and time-of-flight mass spectrometry (TOFMS) imaging are used for visualizing the spatial distribution of analytes. Mass spectrometry (MS) imaging of a sample with a rough surface with a uniform distribution of an analyte does not provide uniform ion intensities in the image. A shift in the value of the analyte ions is also observed.

View Article and Find Full Text PDF

MALDI mass spectrometry imaging (MALDI MSI) is a powerful analytical method for achieving 2D localization of compounds from thin sections of typically but not exclusively biological samples. The dynamically harmonized ICR cell (ParaCell) was recently introduced to achieve extreme spectral resolution capable of providing the isotopic fine structure of ions detected in complex samples. The latest improvement in the ICR technology also includes 2ω detection, which significantly reduces the transient time while preserving the nominal mass resolving power of the ICR cell.

View Article and Find Full Text PDF

Purpose: Gamma index, distance-to-agreement, and dose difference (DD) are commonly used to evaluate planar dose distributions. In this evaluation, the agreement between calculated and measured dose distributions can be susceptible to steep dose gradients along another axis perpendicular to the evaluation plane. Visual registration of the measured dose distribution may be performed to achieve better agreement, although doing so might lose geometric information related to beam targeting in an end-to-end test of intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!