A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Rapid, sensitive and selective detection of glyphosate in wheat and rice flour using a polar stationary phase by LC-MS/MS. | LitMetric

Rapid, sensitive and selective method was studied for the determination of glyphosate in rice and wheat flour using a Raptor Polar column. Samples were extracted with acidified methanol solution. Isotope labeled internal standard was added with the extraction solvent to ensure accurate tracking and quantitation. The glyphosate was analyzed by liquid chromatography tandem mass spectrometry using a Raptor Polar column. Method performance was evaluated through a series of parameters that include accuracy, precision, linearity, limit of detection (LOD), limit of quantitation (LOQ) and matrix effect. Mean recoveries for all matrices were within 96-116% at three fortification levels. Precision for replicates was ≤19% relative standard deviation (RSD%) for wheat and ≤9% RSD% for rice across all fortification levels. Linearity was good for both matrices with a correlation coefficient >0.999 and residual <20% in the concentration range 0.025-1 mg kg. LOD was 0.005 mg kgfor both rice and wheat flour and the LOQ was 0.05 mg kgfor both matrices. The matrix effect was also studied. A successful method for the analysis of glyphosate in wheat and rice flour assure that the criteria of acceptability of the maximum residue levels (MRLs) are insured.

Download full-text PDF

Source
http://dx.doi.org/10.1080/03601234.2022.2042153DOI Listing

Publication Analysis

Top Keywords

rapid sensitive
8
sensitive selective
8
raptor polar
8
polar column
8
fortification levels
8
selective detection
4
detection glyphosate
4
glyphosate wheat
4
wheat rice
4
rice flour
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!