Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Quantifying total organic fluorine (TOF) in water is vital in monitoring the occurrence and persistence of all fluorine-containing organic compounds in the environment, while currently most studies focus on analyzing individual fluorine-containing organic compounds. To fill the technology gap, we herein proposed to convert TOF completely into fluoride with vacuum ultraviolet (VUV) photolysis, followed by analysis of fluoride with ion chromatography. Results showed that the tailored VUV photoreactor achieved satisfying recoveries of fluorine from ten model TOF compounds not only in ultrapure water (83.9 ± 2.0% to 109.4 ± 0.8%) but also in real water samples (92.1 ± 1.0%-106.2 ± 15.7%). Unlike other ultraviolet-based processes that favor alkaline conditions, this VUV process preferred either neutral or acidic conditions to defluorinate selected compounds. While the mechanisms remain to be explored in the future, it has been evidenced that the photo-degradation and photo-defluorination rates of these TOF compounds varied significantly among compounds and operation conditions. The method obtained a method detection limit (MDL) of 0.15 μg-F/L, which is lower than the MDLs of many other TOF analytical methods, along with excellent calibration curves for concentrations ranging from 0.01 to 10.0 mg-F/L. Notably, minimizing fluoride in sample prior to photoconversion was necessary to avoid subtraction-induced errors for TOF measurement, especially when the fluoride/TOF ratio was high. The robust VUV is also green for sample pretreatment due to its unreliance of chemicals or additives.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jhazmat.2022.128389 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!