Purpose: To ease anesthesia and inpatient strain during the COVID-19 pandemic, our institution's policy for hybrid intracavitary-interstitial brachytherapy (IC/ISBT) for cervical cancer (CC) was modified from multiple applications (MA) treated over 2 separate weeks (7 Gy × 4) to a single-application (SA), treated within 1 week (8 Gy × 3). Here, we assessed dosimetric quality of the SA hybrid IC/ISBT approach and report our early outcomes.

Material And Methods: This was an IRB-approved retrospective review of CC patients treated with magnetic resonance imaging (MRI)-guided hybrid IC/ISBT between April 1, 2020 and December 31, 2020 (COVID cohort). Treatment parameters and quality indicators were compared to hybrid IC/ISBT cases treated in 2 years prior (pre-COVID cohort). Differences between cohorts were evaluated with the Mann-Whitney -test.

Results: In the COVID compared to pre-COVID cohort, median high-risk clinical target volume (HR-CTV) was similar: 33.3 vs. 33.9 cc, as was cumulative HR-CTV D: 81.2 vs. 80.9 Gy. Organ-at-risk D values and recto-vaginal point doses were similar. Median number of channels loaded was increased to 6 vs. 4 ( = 0.002), but percentage of total dwell time allocated to needles remained similar: 13% vs. 15%. Median implant HR-CTV D was higher: 107.8% vs. 98.4% ( = 0.001), and there was a trend toward reduced overall treatment time (OTT): 44 days vs. 53 days ( = 0.1). Local control was achieved in all patients, but mucosal toxicity was higher in the COVID group, with grade 2 or higher vaginal, genitourinary, or gastrointestinal events recorded in 56% of the patients.

Conclusions: The SA hybrid IC/ISBT approach utilized during the COVID-19 pandemic maintained similar plan characteristics as pre-pandemic MA hybrid cases, while simultaneously reducing anesthesia, inpatient resources, and OTT. Local control outcomes demonstrate the regimen was effective; however, given the increased risk of mucosal toxicity, we conclude that the SA regimen should be considered only when a MA schedule is not feasible.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8867238PMC
http://dx.doi.org/10.5114/jcb.2022.113058DOI Listing

Publication Analysis

Top Keywords

hybrid ic/isbt
16
covid-19 pandemic
12
cervical cancer
8
anesthesia inpatient
8
ic/isbt approach
8
pre-covid cohort
8
local control
8
mucosal toxicity
8
hybrid
7
ic/isbt
5

Similar Publications

Purpose: To compare inverse planning simulated annealing (IPSA) and hybrid inverse planning optimization (HIPO) using dosimetric and radiobiological models, and provide a basis for selecting the optimization method for cervical cancer.

Material And Methods: This was a retrospective study including 32 patients with radical cervical cancer. Brachytherapy treatment plans were re-optimized using IPSA, HIPO1 (with a locked uterine tube), and HIPO2 (with an unlocked uterine tube).

View Article and Find Full Text PDF

Purpose: This study retrospectively compared the clinical and toxicity outcomes for the cervical cancer of the MRI-guided two adaptive brachytherapy (IGABT) fractions versus one IGABT fraction in one application.

Methods: One hundred and twenty patients with cervical cancer received external beam radiotherapy combined with or without concurrent chemotherapy, which was followed by the IGABT. The IGABT in 63 patients had one IGABT in each application (Arm 1), while in the other 57 patients, at least one treatment was two continuous IGABT every other day in one application (Arm 2).

View Article and Find Full Text PDF

(1) Aim: To compare the treatment plans of stereotactic body radiotherapy (SBRT) with CyberKnife (CK) and high-dose-rate (HDR) intracavitary/interstitial brachytherapy (IC/ISBT) and examine the feasibility of CK-SBRT as a viable alternative to BT in patients with locally advanced cervical cancer (LACC). (2) Methods: A BT plan of 28 Gy in four fractions delivered previously to 20 patients with LACC was compared with a CK plan based on the same CT images with structures delineation for BT. The SBRT treatment plan was further divided according to two different approaches, with the high-risk planning target volume (HR-PTV) defined by the high-risk clinical target volume (HR-CTV) without and with a 5 mm margin, which were named CK-CTV plan and CK-PTV plan, respectively.

View Article and Find Full Text PDF

Purpose: To ease anesthesia and inpatient strain during the COVID-19 pandemic, our institution's policy for hybrid intracavitary-interstitial brachytherapy (IC/ISBT) for cervical cancer (CC) was modified from multiple applications (MA) treated over 2 separate weeks (7 Gy × 4) to a single-application (SA), treated within 1 week (8 Gy × 3). Here, we assessed dosimetric quality of the SA hybrid IC/ISBT approach and report our early outcomes.

Material And Methods: This was an IRB-approved retrospective review of CC patients treated with magnetic resonance imaging (MRI)-guided hybrid IC/ISBT between April 1, 2020 and December 31, 2020 (COVID cohort).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!