Single port surgery in pediatric age: report of first 300 cases.

Minerva Surg

Unit of Pediatric Surgery, Department of Surgery, Dentistry, Pediatrics and Gynecology, Woman and Child Hospital, University of Verona, Verona, Italy.

Published: February 2023

Background: In recent years, evolution of surgery has led to laparoscopy and then to single port surgery. In pediatric age, few papers have been published about single port procedures; in particular, no one has described the use of the Octoport device (Frankenman International Ltd., Suzhou, China). We present our experience using a new device.

Methods: A retrospective analysis of first 300 cases was performed collecting the data of all patients treated with Octoport device from October 2017 to September 2021. Epidemiological data, diagnosis, operative times, and complications were analyzed. Postoperative pain was compared with standard laparoscopy.

Results: A total of 300 procedures were performed during the study period. The age range was 1-17 years. The conversion rate was 3.6% (11 patients) including both conversion to traditional laparoscopy and to laparotomy. Pain management was comparable to traditional laparoscopy. The complication rate was 3.6%, in one case leading to re-do surgery. All the cases in our Unit were successfully completed, with complications mainly related to the original pathology rather than to the technique itself.

Conclusions: The learning curve for Octoport use proved to be functional as for standard laparoscopy. In this study, surgical indications for the use of single port laparoscopy were defined, discerning favorable and unfavorable procedures. A proven superiority of this technique over traditional laparoscopy is yet to be defined, but Octoport has proved to be a safe and easy tool to reduce invasiveness of procedures in pediatric surgery with better cosmetic results.

Download full-text PDF

Source
http://dx.doi.org/10.23736/S2724-5691.22.09315-7DOI Listing

Publication Analysis

Top Keywords

single port
16
traditional laparoscopy
12
port surgery
8
surgery pediatric
8
pediatric age
8
300 cases
8
octoport device
8
rate 36%
8
octoport proved
8
laparoscopy defined
8

Similar Publications

A multipurpose antenna system that can handle a broad area of frequencies is crucial in the effort to build up widespread 5G Internet-of-Things (IoT) networks. For fifth-generation Internet-of-things applications, this research introduces a new multi-band antenna that can operate in the sub-6 GHz band (2-7 GHz), Ku-band (13-17.5 GHz), and millimeter wave band (25-39 GHz).

View Article and Find Full Text PDF

Use of the Da Vinci SP surgical system in robot-assisted nipple-sparing mastectomy: a single-center, retrospective study.

Sci Rep

January 2025

Division of Breast Surgery, Department of Surgery, University of Ulsan College of Medicine, Asan Medical Center, 88, Olympic-ro 43-gil, Songpa-Gu, Seoul, 05505, Republic of Korea.

We investigated the safety and performance of the Da Vinci SP single-port robot (SP robot) in nipple-sparing mastectomy (NSM) with immediate reconstruction. Medical records of 60 women aged ≥ 19 years who had undergone SP robot-assisted unilateral or bilateral NSM with immediate reconstruction between October 2020 and August 2021 were retrospectively analyzed. Stage I (31, 47.

View Article and Find Full Text PDF

Despite advances in neonatal and ophthalmological care, retinopathy of prematurity (ROP) continues to be a leading cause of childhood blindness worldwide. Investigating gene variants associated with vascular responses in ROP may provide valuable insights into its pathogenesis and identify risk or protective factors. Nitric oxide (NO) and endothelin-1 (ET-1) play roles in vascular regulation, influencing processes relevant to ROP development.

View Article and Find Full Text PDF
Article Synopsis
  • Endoscopic-assisted breast surgery (EABS) offers better cosmetic results for breast cancer patients, but traditional axillary lymph node dissection (ALND) requires larger incisions and more retraction.
  • The proposed single-port three-dimensional endoscopic-assisted ALND (S-P 3D E-ALND) uses a minimally invasive technique with high success rates and improved visualization, analyzed from a study of 11 patients.
  • Preliminary results show 100% success without open surgery conversion, short operative times, minimal blood loss, and no significant complications over a median follow-up of 7 months, suggesting that S-P 3D E-ALND is a viable alternative for ALND.
View Article and Find Full Text PDF

Background: Robotic surgery may have shown advantages over conventional laparoscopic surgery, but the da Vinci SP system, which utilizes a single incision, has had limited use in gastric cancer surgery. This study aims to evaluate the short-term outcomes of a novel hybrid technique, minimally invasive laparoscopic and robotic surgery (MILAR), with the da Vinci SP system for gastric cancer.

Materials And Methods: This retrospective study reviewed 23 consecutive patients who underwent gastrectomy for gastric cancer using the MILAR technique with the da Vinci SP system between May and October 2024.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!