Background: Highly cross-linked polyethylene with vitamin E (VE-HXLPE) has shown superior tribological properties and has been rapidly adopted in total hip arthroplasty. However, the majority of studies compare VE-HXLPE to conventional or moderately cross-linked polyethylene using standard femoral head sizes. This study's purpose was 2-fold: (1) compare radiographic femoral head penetration (FHP) between VE-HXLPE and HXLPE and (2) evaluate FHP in large femoral heads ≥40 mm.
Methods: One hundred forty-two consecutive primary total hip arthroplasties using ceramic femoral heads (n = 84 VE-HXLPE; n = 58 HXLPE) in a single implant system were retrospectively reviewed. FHP was measured radiographically utilizing Martell method at 4-week, 1-year, and latest radiographs. FHP, cup position, and demographic variables were compared between VE-HXLPE and HXLPE liners.
Results: Median linear FHP was lower for VE-HXLPE compared to HXLPE during the initial "bedding-in" period between 4-week and 1-year (0.383 vs 0.551 mm, P = .650) and between 1-year and latest follow-up (0.131 vs 0.270 mm/y, P = .636) although without statistical significance. Acetabular cup inclination and anteversion did not influence linear or volumetric FHP (P ≥ .204). Large femoral heads (≥40 mm) were predictive of higher FHP during the early bedding-in period (P ≤ .025) but did not have an effect beyond 1 year in multivariate regression with numbers available. No radiographic osteolysis was observed in any case.
Conclusion: These findings support others that VE-HXLPE is the optimal polyethylene bearing surface to minimize FHP during the bedding-in period and beyond. Surprisingly, large ceramic femoral heads appear to influence FHP during the initial bedding-in period but do not increase FHP beyond 1 year. Further longer term follow-up remains warranted.
Level Of Evidence: III.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.arth.2022.01.075 | DOI Listing |
Knee Surg Sports Traumatol Arthrosc
January 2025
Center for Orthopaedics, Trauma Surgery and Rehabilitation Medicine, University Medicine Greifswald, Greifswald, Germany.
Purpose: The dynamic alignment of the lumbar spine, pelvis and femur is increasingly studied in hip preservation surgery. However, the interaction between lumbopelvic alignment, acetabular and femoral morphology and its influence on patients' preoperative symptom burden remains poorly understood. The aim of this study was to evaluate whether lumbopelvic malalignment affects osseous hip morphology and exacerbates preoperative patient-reported joint functionality in patients undergoing periacetabular osteotomy (PAO).
View Article and Find Full Text PDFJ Orthop Surg Res
January 2025
The Third Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, 510378, P. R. China.
Background: The location and size of necrotic lesions are important factors for collapse, The preserved angles (PAs) are divided into anterior preserved angle (APA) and lateral preserved angle (LPA), which could accurately measure the location of necrosis lesion. We used them to evaluate the effect of the location and size of necrotic lesions on collapse by finite element analysis, to offer a framework for evaluating the prognosis of osteonecrosis of the femoral head (ONFH) in clinical settings.
Methods: 3 left hip models were constructed based on CT data.
BMC Med Inform Decis Mak
January 2025
Department of Orthopedics, the First Hospital of Jilin University, Changchun, Jilin Province, 130021, China.
Purpose: Identifying patients who may benefit from multiple drilling are crucial. Hence, the purpose of the study is to utilize radiomics and deep learning for predicting no-collapse survival in patients with femoral head osteonecrosis.
Methods: Patients who underwent multiple drilling were enrolled.
Iowa Orthop J
January 2025
Rothman Orthopaedic Institute, Philadelphia, Pennsylvania, USA.
Background: Dislocation remains a common complication following total hip arthroplasty (THA). Previous literature has shown that the femoral head-to-neck ratio is essential in hip motion, function, and stability. While large femoral heads and dual mobility bearings have been developed to improve stability, it remains unknown if the ratio between femoral head size to acetabular cup size also plays a role in stability.
View Article and Find Full Text PDFJ Child Orthop
January 2025
Department of Pediatric Orthopaedics and Traumatology, Poznan University of Medical Sciences, Poznan, Poland.
Purpose: Our study aimed to present health-related quality of life (HRQL) after combined bone reconstruction in nonambulatory patients with cerebral palsy (CP) after at least a 2-year follow-up and to assess its impact on HRQL using the Caregiver Priorities and Child Health Index of Life with Disabilities questionnaire (CPCHILD) as the primary outcome measure.
Methods: In this prospective study, we analyzed 31 nonambulatory patients with spastic or mixed CP (GMFCS levels IV-V) who underwent hip reconstructive surgery between 2015 and 2021. The surgical procedures included one-sided varus derotation osteotomy of the femur with Dega transiliac osteotomy and, on the opposite side, varus derotation osteotomy (VDRO) of the femur with shortening and, as needed, Dega pelvic osteotomy.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!