Titanium fixation devices are the gold standard for the treatment of mandibular fractures; however, they present serious limitations, such as non-degradability and generation of imaging artifacts. As an alternative, biodegradable magnesium alloys have lately drawn attention due to their biodegradability and biocompatibility. In addition, magnesium alloys offer a relatively high modulus of elasticity in comparison to biodegradable polymers, being a potential option to substitute titanium in highly loaded anatomical areas, such as the mandible. This study aimed to evaluate the biomechanical competence of magnesium alloy WE43 plates for mandibular fracture fixation in comparison to the clinical standard or even softer polymer solutions. A 3D finite element model of the human mandible was developed, and four different fracture scenarios were simulated, together with physiological post-operative loading and boundary conditions. In a systematic comparison, the material properties of titanium alloy Ti-6Al-4V, magnesium alloy WE43, and polylactic acid (PLA) were assigned to the fixation devices, and two different plate thicknesses were tested. No failure was predicted in the fixation devices for any of the tested materials. Moreover, the magnesium and titanium fixation devices induced a similar amount of strain within the healing regions. On the other hand, the PLA devices led to higher mechanical strains within the healing region. Plate thickness only slightly influenced the primary fixation stability. Therefore, magnesium alloy WE43 fixation devices seem to provide a suitable biomechanical environment to support mandibular fracture healing in the early stages of bone healing. Magnesium WE43 showed a biomechanical performance similar to clinically used titanium devices with the added advantages of biodegradability and radiopacity, and at the same time it showed a remarkably higher primary stability compared to PLA fixation devices, which appear to be too unstable, especially in the posterior and more loaded mandibular fracture cases.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8866862 | PMC |
http://dx.doi.org/10.3389/fbioe.2021.803103 | DOI Listing |
BMC Surg
January 2025
Department of Orthopedics, Nanjing Drum Tower Hospital Group Suqian Hospital, Suqian, China.
Background: To explore the advantages of a lateral tibial locking plate combined with Jail screw fixation in the treatment of anterolateral tibial plateau collapse fracture (ATPCF).
Methods: A retrospective analysis was conducted on patients with ATPCFs admitted to our hospital from February 2019 to February 2023. Twenty-six patients were successfully included, including 15 males and 11 females, with an average age of 58.
Neurochirurgie
January 2025
Department of Neurosurgery, Hôpital de la Timone, APHM. 264 rue Saint-Pierre, 13005, Marseille, France. Electronic address:
Objective: To report the outcomes of transoral C2 osteotomy (or partial odontoidectomy) and posterior fixation, regarding efficacy and safety, in patients with severe irreducible atlantoaxial dislocation (IAAD) following odontoid fracture.
Methods: Transoral C2 osteotomy, soft tissue resection, with or without facet joint release, followed by posterior fixation were performed on 3 patients (2012, 2016, 2023) who were suffering from severe IAAD after an odontoid fracture with spinal cord compression. The radiological and clinical outcomes were then assessed.
Eur J Trauma Emerg Surg
January 2025
AO Research Institute Davos, Davos, Switzerland.
Background: Digitally Enhanced Hands-on Surgical Training (DEHST) platform was introduced to overcome the lack of training capabilities for the challenging task of freehand distal interlocking of intramedullary nails. It demonstrates high perceived realism for surgeons, and novices perform significantly better after DEHST training. However, characterization of how performance improves remained unexplored.
View Article and Find Full Text PDFArch Orthop Trauma Surg
January 2025
Division of Orthopaedic Surgery, Oslo University Hospital, Oslo, Norway.
Patients with unstable hemodynamics and unstable pelvic ring injuries are still demanding patients regarding initial treatment and survival. Several concepts were reported during the last 30 years. Mechanical stabilization of the pelvis together with hemorrhage control offer the best treatment option in these patients.
View Article and Find Full Text PDFArch Orthop Trauma Surg
January 2025
Department of Orthopedics and Traumatology, University Medical Center Mainz, Mainz, Germany.
Iliosacral screw osteosynthesis is a widely recognized technique for stabilizing unstable posterior pelvic ring injuries, offering notable advantages, including enhanced mechanical stability, minimal invasiveness, reduced blood loss, and lower infection rates. However, the procedure presents technical challenges due to the complex anatomy of the sacrum and the proximity of critical neurovascular structures. While conventional fluoroscopy remains the primary method for intraoperative guidance, precise preoperative planning using multiplanar reconstructions and three-dimensional volume rendering is crucial for ensuring accurate placement of iliosacral or transsacral screws.