[Purpose] This study investigated the association between generalized joint laxity and knee joint movement in female university students. [Participants and Methods] The study included 21 female university students. Generalized joint laxity was measured using the Beighton criteria for joint hypermobility. Acceleration and angular velocities of the tibia during knee extension were measured along three axes using a triaxial accelerometer. Sampling data were expressed as root mean squares. The Mann-Whitney U test was used to determine differences in the acceleration and angular velocities along each axis between the generalized joint laxity and non-generalized joint laxity groups. Spearman's rank correlations were used to confirm the association between these parameters. [Results] The rotational angular velocity was greater in the generalized joint laxity than in the non-generalized joint laxity group, and we observed a significant correlation between Beighton scores and the X-axis angular velocity. Furthermore, rotational angular velocity was positively correlated with anterior-posterior acceleration and extension angular velocity. [Conclusion] These findings suggest that rotational angular velocity of the tibia during knee extension is associated with generalized joint laxity in female university students.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8860693 | PMC |
http://dx.doi.org/10.1589/jpts.34.131 | DOI Listing |
Gait Posture
January 2025
Department of Orthopedics, Huashan Hospital, Fudan University, Shanghai, China; Academy for Engineering and Technology, Fudan University, Shanghai, China; Shanghai Sixth People's Hospital, Shanghai, China. Electronic address:
Background: Ankle joint moment and reaction force alteration after surgical treatment of chronic ankle instability (CAI) and osteochondral lesions of the talus (OLT) remains unknown.
Research Question: The current study aimed to investigate the in vivo kinetic effects of surgical management on patients with CAI and OLT and conduct a comparison with healthy subjects.
Methods: Eight patients with concurrent CAI and OLT were assessed in a stair descent setting prior to surgical management and one-year postoperatively.
J Sports Med Phys Fitness
January 2025
Department of Orthopedics and Trauma Surgery, BG University Hospital, Bochum, Germany.
Background: So-called scores are a frequently used evaluation system in clinical examinations to assess the function or limitations of a joint such as the shoulder. However, research indicates that these general scores often have limited validity for specific patient groups, such as athletes. Known as a demanding patient population, athletes have unique needs.
View Article and Find Full Text PDFJB JS Open Access
January 2025
Gluck Equine Research Center, Department of Veterinary Science, Martin-Gatton College of Agriculture, Food and Environment, University of Kentucky, Lexington, Kentucky.
Background: Therapies for cartilage restoration are of great interest, but current options provide limited results. In salamanders, interzone (IZN) tissue can regenerate large joint lesions. The mammalian homolog to this tissue exists during fetal development and exhibits remarkable chondrogenesis in vitro.
View Article and Find Full Text PDFJ Spine Surg
December 2024
Department of Neurosurgery, University of Texas Health Science Center at San Antonio, San Antonio, TX, USA.
Atlantoaxial rotatory subluxation (AARS) in the adult population is primarily trauma-induced. Conservative and surgical treatments have both been used successfully in treating AARS. In cases where AARS cannot be reduced by conservative measures, open reduction and fusion is the conventional treatment approach.
View Article and Find Full Text PDFACS Nano
January 2025
College of Energy, Soochow Institute for Energy and Materials Innovations, Jiangsu Provincial Key Laboratory for Advanced Carbon Materials and Wearable Energy Technologies, Soochow University, Suzhou 215006, P. R. China.
Potassium metal batteries (KMBs) hold promise for stationary energy storage with certain cost and resource merits. Nevertheless, their practicability is greatly handicapped by dendrite-related anodes, and the target design of specialized separators to boost anode safety is in its nascent stage. Here, we develop a thermally robust biopolymeric separator customized via a solvent-exchange and amino-siloxane decoration strategy to render durable and safe KMBs.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!