The effect of pre-treatment methods on membrane flux, COD, and total phenol removal efficiencies for membrane treatment of pistachio wastewater.

J Environ Manage

Mersin University, Department of Environmental Engineering, 33343, Mersin, Turkey. Electronic address:

Published: May 2022

In this study, the effect of pre-treatment methods was investigated for membrane treatment of pistachio processing wastewater (PPW). Chemical coagulation, electrocoagulation, and electrooxidation processes were tested as the pretreatment methods to understand the effect of pretreatment on membrane performance. Alum (Al(SO)·18HO), iron (III) chloride (FeCl·6HO) and iron(II) sulfate (Fe(SO)·7HO) were used as coagulant and anionic polyelectrolyte was used as flocculant. Al-Al and Fe-Fe electrode pairs were used in the electrocoagulation experiments while platinum (Pt), boron doped diamond (BDD), and graphite were used in the electrooxidation experiments. UP150, NF270, and NF90 were used as the membranes. Chemical oxygen demand (COD) and total phenol removal efficiencies from wastewater were determined by considering membrane flux. For chemical coagulation experiments, the highest COD removal efficiency was determined as 44.9% for Al(SO).18HO at 1000 mg/L when the wastewater pH value was 8.0. However, the highest total phenol removal efficiencies were obtined as 62.5% at 4000 mg/L for FeCl.6HO at pH 8. For electrocoagulation experiments, the highest COD and total phenol removal efficiencies were determined as 63.9% at pH 4.0 and 74.2% at pH 7.0, respectively, for 100 A/m current density when aluminum electrode pairs were used. For electrooxidation experiments, the highest COD and total phenol removal efficiencies were determined as 61.2% at pH 4.0 and 83.1% at pH 10, respectively, for 200 A/m current density when BDD-Pt electrode pairs were used. Raw PPW and pre-treated PPW with chemical coagulation, electrocoagulation, and electrooxidation processes were progressively further treated with ultrafiltration (UP150) and nanofiltration (NF270, NF90) membranes to improve COD and total phenol removal efficiencies. The results showed that the permeate of NF90 membrane supplied the highest COD (96.0%) and total phenol removal (97.5%) efficiencies for the raw wastewater. However, COD and total phenol removal efficiencies were determined as 98.6% and 100% for electrocoagulation + NF90, 97.9% and 100% for electrooxidation + NF90, 96.6% and 100% for chemical coagulation + NF90, respectively. The steady-state fluxes for NF90 membranes were 2.9, 7.0, and 8.6 L/mh after chemical coagulation, electrooxidation, and electrocoagulation, respectively. The results depicted that electrocoagulation and electrooxidation were the most suitable pre-treatment methods for water recovery using NF90 membrane.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jenvman.2022.114762DOI Listing

Publication Analysis

Top Keywords

total phenol
32
phenol removal
32
removal efficiencies
28
cod total
24
chemical coagulation
16
highest cod
16
pre-treatment methods
12
electrocoagulation electrooxidation
12
electrode pairs
12
nf90 membranes
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!