Background: After severe trauma of lower limbs, bone, tendon or plate graft exposure is common. The traditional repair method is to use a variety of skin flap transplantation to cover the exposed part, but the wound often can not heal after operation, or the wound is cracked, ulcer, sinus, bone and steel plate are exposed again after wound healing. The reason for this result is that when the flap is covered, the space around the bone plate is not well closed, forming a dead cavity, blood and exudate accumulation, hematoma formation or infection, and finally the wound ruptures again. In addition, due to the swelling and contracture of the flap after operation, the suture tension between the flap and the receiving area becomes larger, the skin becomes thinner and broken, and then the wound is formed. In order to solve the above problems, we carried out the study of artificial true skin embedding combined with fascial sleeve flap transplantation in the treatment of chronic bone plate exposed wounds of lower limbs.

Methods: In this paper, 11 cases of chronic wounds with bone exposure and skin necrosis after steel plate implantation were selected. First stage is the wound bed preparation including primary wound expansion, removal of necrotic tissue and incision of sinus wall, removal of deep necrotic bone and fibrotic scarred skin on the outer wall of steel plate to normal tissue on the outer edge of the wound, removal of precipitated peptone and purulent fur in the hole, periphery and bone space of the steel plate, and removal of tendon tissue with basal necrosis and disintegration of the wound. After vacuum sealing drainage (VSD) 1-2 weeks, the peritraumatic basal granulation tissue grew well and there was no necrotic tissue in the wound. In the second stage, the exposed bone was covered with artificial dermis, the steel plate hole or the periphery and the basal space were filled, and the exposed steel plate was completely embedded, and then the fascia sleeve flap was transplanted to cover the wound. The sural neurovascular flap was performed in nine cases and the lateral superior malleolar artery perforator flap in two case.

Results: The flap survived well in all 11 cases. During the follow-up of 6 months to the removal of the plate, there was no case of rupture, exposure and sinus formation.

Conclusions: Artificial dermal covering combined with fascial sleeve flap transplantation can effectively avoid wound dehiscence or sinus formation caused by foreign body retention, infection and flap contracture. It has good effect in repairing chronic wounds with bone plate exposure after severe trauma of lower limbs.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8882289PMC
http://dx.doi.org/10.1186/s12893-022-01521-2DOI Listing

Publication Analysis

Top Keywords

steel plate
24
sleeve flap
16
flap transplantation
16
bone plate
16
combined fascial
12
fascial sleeve
12
flap
12
chronic wounds
12
lower limbs
12
plate
12

Similar Publications

A Comparative In-Vitro Study of the Effectiveness of Several Methods of Sterilizing Endodontic Files.

Cureus

November 2024

Faculty of health and medical technology, Department of Medical Laboratory Technology, Al-Ayen University, Nasiriyah, IRQ.

Background Successful endodontic treatment depends on several elements. The most important of which is the elimination of microorganisms within the root canal system. To achieve this, sterility must be maintained during all steps of the treatment.

View Article and Find Full Text PDF

Lockie, RG, Young, MA, Lanham, SN, Orr, RM, Dawes, JJ, and Nagel, TR. Scenario and shooting performance in incumbent deputy sheriffs/police officers, cadets, and cadets who worked in custody/corrections facilities. J Strength Cond Res XX(X): 000-000, 2024-Job-specific fitness of law enforcement personnel can decline during their careers.

View Article and Find Full Text PDF

Introduction: Cell-processing operations can potentially contaminate biosafety cabinets, which should be maintained sterile. However, unintended contamination can occur owing to the presence of viruses, mycoplasmas, and bacteria in the raw materials. Moreover, although several methods for expunging these contaminants have been proposed, an optimal method has not yet been determined.

View Article and Find Full Text PDF

Objective: This study aimed to evaluate the clinical outcomes and complications of open reduction and internal fixation (ORIF) combined with sartorius muscle iliac bone graft transplantation (SIBFT) in the treatment of displaced femoral neck fractures in middle-aged and young adults.

Methods: A retrospective analysis was performed on 26 patients under the age of 60 with displaced femoral neck fractures (Pauwels III or Garden III-IV) treated at our institution between April 2019 to July 2022. All patients underwent open reduction and internal fixation (ORIF) through the Smith-Petersen (S-P) approach, augmented with a sartorius muscle iliac bone graft transplantation.

View Article and Find Full Text PDF

Open-source cold and hot scientific sheet press for investigating polymer-based material properties.

HardwareX

September 2024

Department of Electrical & Computer Engineering, Western University, 1151 Richmond St., London, Ontario N6A 5B9, Canada.

To produce samples for both material testing and molded sheets/parts, this article details an open-source scientific cold and hot press design. It consists of two independent and modular upper and lower plate (929 cm) assemblies each containing four 125 W insulated steel strip heaters. The steel housing for these heaters is entirely modular and designed for ease of manufacture, assembly, and customization.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!