A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluating of IAQ-Index and TVOC Parameter-Based Sensors for Hazardous Gases Detection and Alarming Systems. | LitMetric

The measurement of air quality parameters for indoor environments is of increasing importance to provide sufficient safety conditions for workers, especially in places including dangerous chemicals and materials such as laboratories, factories, and industrial locations. Indoor air quality index (IAQ-index) and total volatile organic Compounds (TVOC) are two important parameters to measure air impurities or air pollution. Both parameters are widely used in gases sensing applications. In this paper, the IAQ-index and TVOCs have been investigated to identify the best and most flexible solution for air quality threshold selection of hazardous/toxic gases detection and alarming systems. The TVOCs from the SGP30 gas sensor and the IAQ-index from the SGP40 gas sensor were tested with 12 different organic solvents. The two gas sensors are combined with an IoT-based microcontroller for data acquisition and data transfer to an IoT-cloud for further processing, storing, and monitoring purposes. Extensive tests of both sensors were carried out to determine the minimum detectable volume depending on the distance between the sensor node and the leakage source. The test scenarios included static tests in a classical chemical hood, as well as tests with a mobile robot in an automated sample preparation laboratory with different positions.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8876806PMC
http://dx.doi.org/10.3390/s22041473DOI Listing

Publication Analysis

Top Keywords

air quality
12
gases detection
8
detection alarming
8
alarming systems
8
gas sensor
8
air
5
evaluating iaq-index
4
iaq-index tvoc
4
tvoc parameter-based
4
parameter-based sensors
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!