A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Electronegative electroretinogram in the modern multimodal imaging era. | LitMetric

Electronegative electroretinogram in the modern multimodal imaging era.

Clin Exp Ophthalmol

Visual electrophysiology Unit, Save Sight Institute, Speciality of Clinical Ophthalmology and Eye Health, Faculty of Medicine and Health, The University of Sydney, Sydney, New South Wales, Australia.

Published: May 2022

Background: The electronegative electroretinogram (ERG) reflecting inner retinal dysfunction can assist as a diagnostic tool to determine the anatomical location in eye disease. The aim of this study is to determine the frequency and aetiology of electronegative ERG in a tertiary ophthalmology centre and to develop a clinical algorithm to assist patient management.

Methods: Retrospective review of ERGs performed at the Save Sight Institute from January 2011 to December 2020. ERGs were performed according to ISCEV standard. The b:a ratio was analysed in dark adapted (DA) 3.0 or 12.0 recordings. Patients with ratio of ≤1.0 were included.

Results: A total of 4421 patients had ERGs performed during study period, of which 139 patients (3.1%) had electronegative ERG. The electronegative ERG patients' median age at referral time was 37 (0.7-90.6) years. The causative aetiologies were photoreceptor dystrophy (48, 34.5%), Congenital Stationary Night Blindness (CSNB) (33, 23.7%), retinal ischemia (18, 12.9%), retinoschisis (15, 10.8%), paraneoplastic autoimmune retinopathy (PAIR) and nonPAIR (14, 10.1%), batten disease (4, 2.9%), and inflammatory retinopathy (4, 2.9%). There were three patients with an unclassified diagnosis. Thirty-two patients (23%) had good vision and a normal fundus appearance. Eleven patients (7.9%) had good vision and normal results in all multimodal imaging.

Conclusions: The frequency of electronegative ERG in our referral centre was 3.1% with photoreceptor dystrophy as the main aetiology. A significant number of the cases had good vision with normal fundus or normal multimodal imaging. This further highlights the value of an ERG in this modern multimodal imaging era.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9544723PMC
http://dx.doi.org/10.1111/ceo.14065DOI Listing

Publication Analysis

Top Keywords

electronegative erg
16
multimodal imaging
12
ergs performed
12
good vision
12
vision normal
12
electronegative electroretinogram
8
modern multimodal
8
imaging era
8
photoreceptor dystrophy
8
normal fundus
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!