Differences in UV-C LED Inactivation of Serogroups in Drinking Water.

Microorganisms

US Environmental Protection Agency (USEPA), Office of Research and Development (ORD), Center for Environmental Solutions & Emergency Response (CESER), Homeland Security and Materials Management Division, Cincinnati, OH 45268, USA.

Published: February 2022

(Lp) is an opportunistic pathogen that causes respiratory infections primarily through inhalation of contaminated aerosols. Lp can colonize premise plumbing systems due to favorable growth conditions (e.g., lower disinfectant residual, stagnation, warm temperatures). UV-C light-emitting diodes (UV-C LEDs) are an emerging water treatment technology and have been shown to effectively inactivate waterborne pathogens. In this study, the inactivation of four Lp strains (three clinical sg1, 4, and 6; and one sg1 drinking water (DW) isolate) was evaluated using a UV-C LED collimated beam at three wavelengths (255, 265, and 280 nm) and six fluence rates (0.5-34 mJ/cm). Exposure to 255 nm resulted in higher log reductions at the lower fluences compared to exposures at 265 and 280 nm. Efficacy testing was also performed using a UV-C LED point-of-entry (POE) flow-through device. Based on the log inactivation curves, at 255 nm, the sg4 and sg6 clinical isolates were more susceptible to inactivation compared to the two sg1 isolates. However, at 265 and 280 nm, the sg1 and sg4 clinical isolates were more resistant to inactivation compared to the sg6 clinical and sg1 DW isolates. Differential log reductions were also observed using the POE device. Results indicate that although UV-C LED disinfection is effective, variations in Lp inactivation, wavelengths, and technology applications should be considered, especially when targeting specific isolates within premise plumbing systems.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8877565PMC
http://dx.doi.org/10.3390/microorganisms10020352DOI Listing

Publication Analysis

Top Keywords

uv-c led
16
265 280
12
drinking water
8
premise plumbing
8
plumbing systems
8
clinical sg1
8
log reductions
8
sg6 clinical
8
clinical isolates
8
inactivation compared
8

Similar Publications

Studies on the Virucidal Effects of UV-C of 233 nm and 275 nm Wavelengths.

Viruses

December 2024

Institute of Hygiene and Environmental Medicine, University Medicine Greifswald, Ferdinand-Sauerbruch-Str., 17475 Greifswald, Germany.

Among the physical decontamination methods, treatment with ultraviolet (UV) radiation is a suitable means of preventing viral infections. Mercury vapor lamps (254 nm) used for room decontamination are potentially damaging to human skin (radiation) and harmful to the environment (mercury). Therefore, other UV-C wavelengths (100-280 nm) may be effective for virus inactivation on skin without damaging it, e.

View Article and Find Full Text PDF

Comparison of the Effects of UV-C Light in the Form of Flash or Continuous Exposure: A Transcriptomic Analysis on L.

Int J Mol Sci

December 2024

Unité Propre de Recherche Innovante, ERIT Plant Science, Interactions and Innovation, Avignon Université, 301 Rue Baruch de Spinoza, 84140 Avignon, France.

Ultraviolet C (UV-C) flash treatment represents a promising method for priming plants. This study compared the effects of 1 s (flash) and 60 s (60 s) UV-C exposures on the transcriptome of L. plants.

View Article and Find Full Text PDF

: In environments with high-frequency contact surfaces, drug-resistant bacteria, such as carbapenem-resistant and methicillin-resistant (MRSA), can survive for extended periods, contributing to healthcare-associated infections. Ultraviolet (UV)-C irradiation often fails to adequately disinfect shadowed areas, leading to a persistent contamination risk. We evaluated the effectiveness of using a UV-C containment unit (UVCCU) in conjunction with UV-C irradiation to improve the sterilization effects on both direct and indirect surfaces, including shadowed areas, and to assess the leakage of UV radiation to the surroundings.

View Article and Find Full Text PDF

The airborne transmission of infectious diseases and bioaerosol-induced cross-contamination pose significant challenges in the food, dairy, and pharma industries. This study evaluated the effectiveness of 279 nm UV-C LED irradiation for decontaminating bioaerosols, specifically containing microorganisms such as (C3040- Kanamycin resistant), Enteritidis (ATCC 4931), and (ATCC 4973), on food contact surfaces. Borosilicate glass, silicon rubber, and stainless steel (316L) surfaces were selected for experimentation for their usage in the food industry.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!