The present research investigates the effect of a heat source/sink on nanofluid flow through a cone, wedge, and plate when using a suspension of aluminium alloys (AA7072 and AA7075) as nanoparticles in base fluid water. The activation energy and porous material are also considered in the modelling. Using similarity transformations, the modelling equations were converted into an ordinary differential equation (ODEs) system. The Runge Kutta Fehlberg 45 fourth fifth-order (RKF 45) technique and shooting approach were used to numerically solve these equations. The influence of essential aspects on flow fields, heat, and mass transfer rates was studied and addressed using graphical representations. The outcome reveals that the case of fluid flow past a plate shows improved heat transfer for augmented heat source/sink parameter values than the cases for fluid flow past a cone and wedge does. Furthermore, we observed the least heat transfer for the case of fluid flow past the cone. The mass transfer for the case of fluid flow past the cone increased more slowly for growing activation energy parameter values than in the other cases. Moreover, we observed higher mass transfer rates for the case of fluid flow past the plate. The augmented values of the heat source/sink parameter decayed the heat transfer rate in all three flow cases.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8876240PMC
http://dx.doi.org/10.3390/mi13020302DOI Listing

Publication Analysis

Top Keywords

fluid flow
20
flow cone
16
case fluid
16
activation energy
12
cone wedge
12
heat source/sink
12
mass transfer
12
heat transfer
12
flow
9
wedge plate
8

Similar Publications

Guided wave tomography of pipe bends based on full waveform inversion.

Ultrasonics

January 2025

Department of Civil Engineering and Architecture, Tallinn University of Technology, Ehitajate tee 5, 19086, Tallinn, Estonia. Electronic address:

Pipe bends are recognized as critical areas susceptible to wall thinning, a phenomenon instigated by abrupt changes in the fluid flow direction and velocity. Conventional monitoring techniques for bends typically depend on localized ultrasonic measurements of thickness. While these methods are effective, they can be time-consuming compared to the use of permanently installed transducers, a strategy employed in guided wave tomography (GWT).

View Article and Find Full Text PDF

Nanoporous metals, a class of free-standing, high specific-area materials, evolve from interface-controlled self-organization in a selective dissolution (e.g., dealloying).

View Article and Find Full Text PDF

Canopy flows occur when a moving fluid encounters a matrix of free-standing obstacles and are found in diverse systems, from forests and marine ecology to urban landscapes and biology (e.g. cilia arrays).

View Article and Find Full Text PDF

Comparison of treatments for equine laryngeal hemiplegia using computational fluid dynamic analysis in an equine head model.

Front Vet Sci

December 2024

Department of Large Animal Clinical Sciences, Western College of Veterinary Medicine, University of Saskatchewan, Saskatoon, SK, Canada.

Introduction: Computational fluid dynamics (CFD) is gaining momentum as a useful mechanism for analyzing obstructive disorders and surgeries in humans and warrants further development for application in equine surgery. While advancements in procedures continue, much remains unknown about the specific impact that different surgeries have on obstructive airway disorders. The objective of this study was to apply CFD analysis to an equine head inhalation model replicating recurrent laryngeal neuropathy (RLN) and four surgical procedures.

View Article and Find Full Text PDF

How infusion fluids are distributed and eliminated is of importance to how much and how fast they should be administered. This manuscript applies population pharmacokinetic modeling to intravenous infusions of crystalloid fluid, which is a common therapy in hospital care and mandatory during surgery. The analysis was based on the hemodilution and urine output measured during and after 262 infusions of 1647 ± 461 mL (mean ± SD) of fluid over 30 min in adults.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!