This prospective case-control study aimed to compare the intraoperative hemodynamic changes between the wide-awake local anesthesia no tourniquet (WALANT) technique and general anesthesia (GA) in patients undergoing distal radius plating surgery. Forty adults with distal radius fractures underwent plating surgery via the WALANT technique (20 patients) or GA (20 patients). Mean arterial pressure (MAP) and heart rate were recorded. Intraoperative pain intensity was measured using the visual analog scale (VAS) for pain in the WALANT group. The measures of hemodynamics and VAS were recorded at seven-time points perioperatively. The VAS score decreased significantly compared with the preoperative status in the WALANT group for most of the intraoperative period except during injections of local anesthetics and fracture reduction. The intraoperative MAP in the WALANT group showed no significant change during the perioperative period. In addition, the WALANT group showed fewer perioperative MAP fluctuations than the GA group ( < 0.05). The reduction and plating quality were similar between the two groups. WALANT provided a feasible technique with less fluctuation in hemodynamic status. With gentle manipulation of the fracture reduction, distal radius plating surgery using the WALANT technique is a well-tolerated surgical procedure and shows similar reduction and plating quality to GA.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8875852PMC
http://dx.doi.org/10.3390/jcm11041123DOI Listing

Publication Analysis

Top Keywords

distal radius
16
plating surgery
16
walant group
16
radius plating
12
walant technique
12
wide-awake local
8
local anesthesia
8
anesthesia tourniquet
8
technique general
8
general anesthesia
8

Similar Publications

Introduction: Regional anesthesia increases in popularity in orthopaedic surgery. It is usually applied in elective surgeries of the extremities. The aim of this study was to assess indication of the use of general anesthesia in the surgical treatment of distal radius fractures.

View Article and Find Full Text PDF

Case: A 41-year old man fell from height sustaining displaced radial shaft and ulnar styloid fractures underwent open reduction internal fixation of the radius with early recognition of a radiocapitellar dislocation and longitudinal forearm instability in the early postoperative period. Revision surgery was performed 13 days postoperatively involving annular ligament reconstruction, elbow spanning external fixation, and distal radioulnar joint stabilization. Favorable functional and radiographic outcomes are shown at 1-year follow-up.

View Article and Find Full Text PDF

We report a series of 12 patients who developed early distal radioulnar joint subluxation after a distal radial fracture, not present on the initial radiographs. Early identification and management of this condition can give good clinical results. IV.

View Article and Find Full Text PDF

Treatment of anterior rim fractures of the distal radius with an anterior rim plate: A retrospective study.

J Hand Surg Eur Vol

January 2025

Department of Orthopedics, E-Da Hospital, I-Shou University/School of Medicine, College of Medicine, I-Shou University, Kaohsiung, Taiwan.

Treatment of distal radial fractures that include small anterior rim fragments can be difficult. We retrospectively reviewed 19 patients in whom an anterior rim plate with locking screws was used. After a median follow-up of 18 months (range 6-32; interquartile range (IQR) 14, 26), the median wrist flexion and extension arc was 70° (range 50-80; IQR 60, 70), the median grip strength was 80% of the contralateral side (range 52-104; IQR 77, 88), the median visual analogue scale score for pain was 0 (range 0-5; IQR 0, 1), the median disabilities of the arm, shoulder and hand score was 2 (range 0-59; IQR 0, 11) and the median modified Mayo wrist score was 80 (range 35-100; IQR 75, 85).

View Article and Find Full Text PDF

The main objectives of this work are to validate a 1D-0D unsteady solver with a distributed stenosis model for the patient-specific estimation of resting haemodynamic indices and to assess the sensitivity of instantaneous wave-free ratio (iFR) predictions to uncertainties in input parameters. We considered 52 patients with stable coronary artery disease, for which 81 invasive iFR measurements were available. We validated the performance of our solver compared to 3D steady-state and transient results and invasive measurements.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!