This study was conducted to measured talar displacement using ultrasound during an anterior drawer test (ADT) with a Telos device. Five adults (3 men and 2 women; 8 ankles; mean age: 23.2 y) with a history of ankle sprain and eight adults (5 men and 3 women; 16 ankles; mean age: 22.1 y) without a history of ankle sprain were recruited into a history of ankle sprain (HAS) and a control group, respectively. Talar displacement was observed in response to load forces applied by a Telos device during the ultrasound stress imaging test. The ultrasound probe was placed 5 mm inside from the center of the Achilles tendon on the posterior ankle along the direction of the major axis. The inter-rater reliability for the present method was classified as good and excellent (ICC = 0.858 and 0.957 at 120 N and 150 N, respectively) in the control group and excellent (ICC = 0.940 and 0.905 at 120 N and 150 N, respectively) in the HAS group, according to specific intraclass correlation coefficient values. We found that talar displacement during the ADT was lower in the HAS group than in the control group. Analysis of the receiver operating characteristic curve revealed that the quantitative ultrasound-based ADT using a Telos device was superior to the X-ray-based test in detecting reduced ankle joint mobility during the ADT (area under the curve of 0.905 and 0.726 at a force of 150 N using ultrasound-based and X-ray-based tests, respectively). Further investigation is needed; nevertheless, this preliminary study suggests that the ultrasound-based quantitative ADT using a Telos device might detect talar displacement more sensitively than the conventional stress X-ray.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8874523PMC
http://dx.doi.org/10.3390/ijerph19042367DOI Listing

Publication Analysis

Top Keywords

talar displacement
20
telos device
20
adt telos
12
history ankle
12
ankle sprain
12
control group
12
anterior drawer
8
preliminary study
8
adults men
8
men women
8

Similar Publications

Comparison of Biocompatibility of 3D-Printed Ceramic and Titanium in Micropig Ankle Hemiarthroplasty.

Biomedicines

November 2024

Division in Anatomy and Developmental Biology, Department of Oral Biology, Human Identification Research Institute, BK21 FOUR Project, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul 03722, Republic of Korea.

Background: Ankle arthritis is a common degenerative disease that progresses as cartilage damage in the lower tibia and upper talus progresses, resulting in loss of joint function. In addition to typical arthritis, there is also structural bone loss in the talus due to diseases such as talar avascular necrosis. Total talus replacement surgery is the procedure of choice in end-stage ankle arthritis and consists of a tibial, talar component and an insert.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates ballistic talus fractures, which are challenging to treat, highlighting the need for more research on these injuries.
  • A retrospective analysis included 21 patients with talus fractures, revealing that over half were displaced and many had additional injuries to the foot and ankle.
  • The findings indicated that surgical treatment improved the talar declination angle for those fractures but had notable complications, with a 29% complication rate, including cases of avascular necrosis.
View Article and Find Full Text PDF

Purpose: To explore the efficacy and feasibility of arthroscopy combined with bone tunnel technique in treating Berndt and Harty stage III or IV osteochondral lesions of the talus (OLT).

Methods: A retrospective analysis was conducted on the clinical data of 21 patients with Berndt and Harty stage III or IV OLT who underwent surgical treatment at our institution from September 2017 to September 2022. Under arthroscopy, the displaced talar osteochondral lesion was restored.

View Article and Find Full Text PDF

Background: The surgical treatment and management of postoperative soft tissue complications in diabetic patients with displaced calcaneal fractures are still controversial. We aimed to evaluate the short-term efficacy of percutaneous minimally invasive screw fixation in treatment of diabetic patients with Sanders II and III calcaneal fractures under subtalar arthroscopy assisted by preoperative musculoskeletal ultrasonic locating lateral calcaneal branch (LCB) of the sural nerve and calcaneal-talar joint distraction device.

Methods: The clinical data of 52 diabetic patients diagnosed with Sanders II or III calcaneal fractures from March 2016 to August 2020 were followed up and analyzed.

View Article and Find Full Text PDF
Article Synopsis
  • * Researchers classified TCC morphologies, analyzed CT and X-ray images, and developed finite element models to simulate stress and strain on TCCs, revealing key anatomical features and imaging signs.
  • * Findings indicate that TCCs are located near specific bone landmarks and exhibit unique morphological traits, emphasizing the importance of accurate imaging in diagnosing TCCs, which can enhance clinical practices.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!