As a convenient device for observing neural activity in the natural environment, portable EEG technology (PEEGT) has an extensive prospect in expanding neuroscience research into natural applications. However, unlike in the laboratory environment, PEEGT is usually applied in a semiconstrained environment, including management and engineering, generating much more artifacts caused by the subjects' activities. Due to the limitations of existing artifacts annotation, the problem limits PEEGT to take advantage of portability and low-test cost, which is a crucial obstacle for the potential application of PEEGT in the natural environment. This paper proposes an intelligent method to identify two leading antecedent causes of EEG artifacts, participant's blinks and head movements, and annotate the time segments of artifacts in real time based on computer vision (CV). Furthermore, it changes the original postprocessing mode based on artifact signal recognition to the preprocessing mode based on artifact behavior recognition by the CV method. Through a comparative experiment with three artifacts mark operators and the CV method, we verify the effectiveness of the method, which lays a foundation for accurate artifact removal in real time in the next step. It enlightens us on how to adopt computer technology to conduct large-scale neurotesting in a natural semiconstrained environment outside the laboratory without expensive laboratory equipment or high manual costs.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8858064PMC
http://dx.doi.org/10.1155/2022/9590411DOI Listing

Publication Analysis

Top Keywords

semiconstrained environment
12
intelligent method
8
portable eeg
8
based computer
8
computer vision
8
natural environment
8
real time
8
mode based
8
based artifact
8
environment
6

Similar Publications

As a convenient device for observing neural activity in the natural environment, portable EEG technology (PEEGT) has an extensive prospect in expanding neuroscience research into natural applications. However, unlike in the laboratory environment, PEEGT is usually applied in a semiconstrained environment, including management and engineering, generating much more artifacts caused by the subjects' activities. Due to the limitations of existing artifacts annotation, the problem limits PEEGT to take advantage of portability and low-test cost, which is a crucial obstacle for the potential application of PEEGT in the natural environment.

View Article and Find Full Text PDF

Introduction: With the rapid development of transportation infrastructures in precipitous areas, the mileage of freeway tunnels in China has been mounting during the past decade. Provided the semi-constrained space and the monotonous driving environment of freeway tunnels, safety concerns still remain. This study aims to investigate the uniqueness of the relationships between crash severity in freeway tunnels and various contributory factors.

View Article and Find Full Text PDF

A biomechanical investigation of dual growing rods used for fusionless scoliosis correction.

Clin Biomech (Bristol)

January 2015

Paediatric Spine Research Group, Institute of Health and Biomedical Innovation, Queensland University of Technology and Mater Health Services, Brisbane, Australia.

Background: The use of dual growing rods is a fusionless surgical approach to the treatment of early onset scoliosis which aims to harness potential growth and correct spinal deformity. The purpose of this study was to compare the in-vitro biomechanical response of two different dual rod designs under axial rotation loading.

Methods: Six porcine spines were dissected into seven level thoracolumbar multi-segment units.

View Article and Find Full Text PDF

Background: Wear debris of polyethylene within joint replacement systems can result in clinical complications including osteolysis and component loosening. Highly crosslinked polyethylene (HXPE) was introduced to improve these outcomes, and has been shown to result in improved wear performance in several joint replacement systems. However, bearing couples within total ankle replacement (TAR) systems have historically used conventional polyethylene (CPE) articulating on metal.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!