The different subtalar ligaments show significant differences in their mechanical properties.

Foot Ankle Surg

Institute for Orthopaedic Research and Training (IORT), Department of Development and Regeneration, Faculty of Medicine, KU Leuven, Leuven, Belgium; Department of Orthopaedics, Foot and Ankle Unit, University Hospitals Leuven, KU Leuven, Leuven, Belgium. Electronic address:

Published: October 2022

Background: Today, the relative contribution of each ligamentous structure in the stability of the subtalar joint is still unclear. The purpose of this study is to assess the material properties of the different ligamentous structures of the subtalar joint.

Methods: Eighteen paired fresh-frozen cadaveric feet were used to obtain bone-ligament-bone complexes of the calcaneofibular ligament (CFL), the cervical ligament (CL) and the anterior capsular ligament-interosseous talocalcaneal ligament complex (ACaL-ITCL). The samples were subjected to uniaxial testing to calculate their respective stiffness and failure load.

Results: The stiffness of ACaL-ITCL complex (mean: 150 ± 51 N/mm, 95% confidence interval (CI): 125.0-176.6 N/mm) was significantly higher than both CFL (mean: 55.8 ± 23.0 N/mm, CI: 43.8-67.7 N/mm) and CL (mean: 63.9 ± 38.0 N/mm, CI: 44.4-83.3 N/mm). The failure load of both the ACaL-ITCL complex (mean:382.5 ± 158 N, CI: 304.1-460.8 N) and the CFL (mean:320.4 ± 122.0 N, CI: 257.5-383.2 N) were significantly higher than that of the CL (mean:163.5 ± 58.0 N, CI: 131.3-195.7 N). The injury pattern demonstrated a partial rupture in all CFL and ACaL-ITCL specimens and in 60% of the CL specimens.

Conclusion: The CFL, CL and ACaL-ITCL show significant differences in their intrinsic mechanical properties. Both the CFL and CL are more compliant ligaments and seem to be involved in the development of subtalar instability. Based on the material properties, a gracilis tendon graft seems more appropriate than a synthetic ligament to reconstruct a CL or CFL. A partial rupture was the most commonly seen injury pattern in all ligaments. A fibular avulsion of the CFL was only rarely seen. The injury patterns need further investigation as they are important to optimize diagnosis and treatment.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.fas.2022.02.008DOI Listing

Publication Analysis

Top Keywords

mechanical properties
8
material properties
8
cfl
8
acal-itcl complex
8
injury pattern
8
partial rupture
8
cfl acal-itcl
8
acal-itcl
5
subtalar
4
subtalar ligaments
4

Similar Publications

The heart, with its complex structural and functional characteristics, plays a critical role in sustaining life by pumping blood throughout the entire body to supply nutrients and oxygen. Engineered heart tissues have been introduced to reproduce heart functions to understand the pathophysiological properties of the heart and to test and develop potential therapeutics. Although numerous studies have been conducted in various fields to increase the functionality of heart tissue to be similar to reality, there are still many difficulties in reproducing the blood-pumping function of the heart.

View Article and Find Full Text PDF

The increasing demand for sustainable food packaging has driven the development of films based on biopolymers. However, enhancing their functional properties remains a challenge. In the current study, potato starch-pectin (PSP) composite films were fabricated and enriched with juniper berry essential oil (JBEO) to improve their physicochemical properties.

View Article and Find Full Text PDF

Introduction: One of the most prevalent healthcare-associated infections in the pediatric intensive care unit is ventilator-associated pneumonia (VAP). VAP not only results in prolonged hospital and intensive care unit (ICU) stays but also imposes higher costs on patients and the healthcare system. Therefore, it is essential to implement preventive measures.

View Article and Find Full Text PDF

Magnetorheological (MR) fluid (MRF) dampers, serving as fail-safe semi-active devices, exhibit nonlinear hysteresis characteristics, emphasizing the necessity for accurate modeling to formulate effective control strategies in smart systems. This paper introduces a novel stop operator-based Prandtl-Ishlinskii (PI) model, featuring a reduced parameter set (seven), designed to estimate the nonlinear hysteresis properties of a large-scale bypass MRF damper with variable stiffness capabilities under varying applied current. With only seven parameters, the model realizes current, displacement, and rate dependencies.

View Article and Find Full Text PDF

Humerus greater tuberosity (HGT) avulsion fracture is one of the most common types of proximal humerus fractures. The presence of motion and gap lead to the failure of implants, due to the force pulling from the supraspinatus. In this work, electrospinning technology was applied to fabricate PCL-PEG/CS/AST nanofiber with superior biocompatibility and mechanical property.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!